Operation
20
334649H
10. Turn prime valve horizontal. Trigger gun
into flushing pail to purge fluid from hose.
11. Engage the trigger lock.
12. Turn pressure control knob to the lowest
pressure setting and turn ON/OFF
switch to
OFF
position. Disconnect
power to sprayer.
13. Remove filter from gun. Clean and
inspect. Install filter. See separate gun
manual.
14. If flushing with water, flush again with
mineral spirits or Pump Armor to leave a
protective coating to prevent freezing or
corrosion.
15. Wipe sprayer, hose and gun with a rag
soaked in water or mineral spirits.
ti25319a
ti25282a
ti25331a
ti25295a
ti24720a