Repair
312063Z
33
Transducers
1. Turn main power OFF
. Disconnect power
supply.
3. Refer to electrical diagrams. Motor control board is
on right side inside cabinet.
4. Disconnect transducer cables at board; see F
page 32. Reverse A and B connections and check if
diagnostic code follows; see
, page 11.
5. If transducer fails test, thread cable through top of
cabinet. Note path as cable must be replaced in
same way.
6. Install o-ring (720) on new transducer (706), F
7. Install transducer in manifold. Mark end of cable
with tape (red=transducer A, blue=transducer B).
8. Route cable into cabinet and thread into bundle as
before.
9. Connect transducer cable at board; see F
. 5, page
32.
Electric Fan
1. Turn main power OFF
. Disconnect power
supply.
3. Check fuses (F) at left of breaker module, F
Replace if blown. If good, continue with step 4.
4. Refer to electrical diagrams. Disconnect fan wires
from fuses (F).
5. Remove fan.
6. Install fan in reverse order.
F
IG
. 6 Transducers
ti9885a
720
706 (B Side)
701
706 (A Side)
F
IG
. 7 Fan Fuses
F
ti9884a-1