Repair
46
313540L
3. Place a pan under reservoir drain plug (110k) to
catch oil.
4. Remove drain plug (110k).
5. Place a rag around base of oil filter (135) to prevent
oil from spilling. Unscrew filter 1/4-3/4 turn to break
air lock in filter. Wait five minutes to allow oil in filter
to drain back into reservoir. Unscrew filter and
remove.
6. Reinstall drain plug (110k).
7. Replace filter (135):
a. Coat filter seal with fresh oil.
b. Screw filter on snug, then an additional 1/4 turn.
8. Refill reservoir with approved hydraulic fluid. See
Table 9.
9. Proceed with normal operation.
NOTE: Upon starting motor, hydraulic pump may
make a screeching noise until primed. If this noise
continues for more than 30 seconds, switch off
motor control. See Hydraulic Drive System, page 22.
F
IG
. 16: Change Hydraulic Fluid and Filter
ti9888a
135
110k