System
System
System
Use the System screen to set system settings.
Setting
Setting
Setting
Description
Description
Description
System Name
System name that is displayed in the
Reactor Connect App.
Proportioner Type
Proportioner model type; see
.
Enable Custom
Pump Sizes
Tap to enable/disable custom pump
sizes.
Pump A Volume
Volume of the A side proportioner
pump. Value is editable if Enable
Custom Pump Sizes is checked.
Pump B Volume
Volume of the B side proportioner
pump. Value is editable if Enable
Custom Pump Sizes is checked.
MCM Digital
Input/Output 1–2
Tap to select Input/Output setting
for the MCM Digital Input/Output
pins 1 and 2 on MCM connector 12.
Input/Output
Input/Output
Input/Output Options:
Options:
Options: Disabled: Do
nothing.
Light
Light
Light Tower
Tower
Tower Red:
Red:
Red: Use to drive the red
light of the accessory Light Tower
Kit.
Light
Light
Light Tower
Tower
Tower Yellow:
Yellow:
Yellow: Use to drive the
yellow light of the accessory Light
Tower Kit.
Light
Light
Light Tower
Tower
Tower Green:
Green:
Green: Use to drive the
green light of the accessory Light
Tower Kit.
MCM Digital
Input/Output 3–4
See MCM Digital Input/Output 1–2.
MCM Digital
Input/Output 5–6
See MCM Digital Input/Output 1–2.
MCM Digital
Input/Output 7–8
See MCM Digital Input/Output 1–2.
Supply
Supply
Supply System
System
System
Use the Supply System screen to set feed system
settings.
Setting
Setting
Setting
Description
Description
Description
Transfer Pump A
Type
Tap to select the type of transfer
pump used to feed the A side of the
proportioner.
Transfer Pump Type Options:
Air:
Air:
Air: select when using an
air/pneumatic transfer pump
(or other non-Graco Electric Transfer
Pump).
Electric:
Electric:
Electric: select when using with
Graco Electric Transfer Pumps.
Transfer Pump B
Type
Tap to select the type of transfer
pump used to feed the B side of the
proportioner. See Transfer Pump A
Type for a list of options.
Enable Smart
Supply
This feature automatically adjusts
the Electric Transfer Pump pressure
setpoint to maintain appropriate inlet
pressure with various chemicals,
ambient conditions and supply
configurations.
NOTE:
NOTE:
NOTE: This feature is automatically
enabled when the inlet pressure
sensors are enabled and at least one
electric transfer pump is installed.
Max Chemical
Volume
Tap to enter the chemical volume of
the supply containers.
Enable Low
Chemical Alarms
Tap the checkbox to enable/disable
Low Chemical Alarms. Tap the
number value to adjust the alarm
threshold.
Enable Inlet
Pressure Sensors
Tap the checkbox to enable/disable
inlet pressure sensors.
NOTE
NOTE
NOTE: Inlet pressure sensors are
automatically enabled if flow meters
are enabled.
Enable Inlet
Temperature
Sensors
Tap the checkbox to enable/disable
inlet temperature sensors.
Enable Low Inlet
Temperature
Alarms
Tap the checkbox to enable/disable
Low Inlet Temperature Alarms. Tap
the number value to adjust the alarm
threshold.
Enable High Inlet
Temperature
Alarms
Tap the checkbox to enable/disable
High Inlet Temperature Alarms. Tap
the number value to adjust the alarm
threshold.
Request Electric
Transfer Pump
Calibration
Tap Electric Transfer Pump
calibration button to queue an
electric transfer pump calibration the
next time the electric transfer pump
is run. Only appears when electric
transfer pumps are selected.
NOTE:
NOTE:
NOTE: After pressing the button,
a notice will appear on the screen
notifying the user the calibration is
queued.