Circulation
Circulation
Circulation Through
Through
Through Gun
Gun
Gun Manifold
Manifold
Manifold
NOTICE
NOTICE
NOTICE
To prevent equipment damage, do not
circulate fluid containing a blowing agent
without consulting with your material supplier
regarding fluid temperature limits.
NOTE:
NOTE:
NOTE: Optimum heat transfer is achieved at
lower fluid flow rates with temperature set
points at desired drum temperature.
Circulating fluid through the gun manifold
allows rapid preheating of the hose.
1. Install the gun manifold (E) on an accessory
circulation block (CK).
The Fusion AP gun manifold is shown.
Circulation
Circulation
Circulation
Gun
Gun
Gun
Manual
Manual
Manual in
in
in
English
English
English
246362
Fusion AP, PC,
MP
309818
256566
Fusion CS
313058
2. Route the circulation lines back to their
respective component A or B supply drum.
See
Typical Installation with gun fluid
manifold to drum circulation, page 17
.
Use hoses rated at the maximum
working pressure of this equipment. See
Technical Specifications, page 59
3. Follow
4. Set temperature targets for ISO
and RES
on the ADM screen.
5. Tap
to turn on the ISO primary
heat zone and
to turn on the RES
primary heat zone.
6. Use jog mode to circulate fluid until ISO
and RES temperatures reach their respective
targets. Reactor systems allow the entire
system to be in jog mode, or A and B-side
transfer pumps to be put into jog mode
separately. See
.
7. Tap
to turn on the hose heat.
8. Tap the Pump
Pump
Pump Mode
Mode
Mode button
9. Select Spray
Spray
Spray mode from the drop down
menu.
10. Set the pressure relief/spray valves (SA, SB)
to spray
.
WWLL EE
38
3A8500B