Setup
334135B
31
Adjust Dispense Valve Snuff
Back
At the end of a shot, a small amount of material is drawn
back into the static mixer to prevent extra material from
being dispensed. If too much snuff back occurs, air will
enter the static mixer and can travel up into the dispense
valve. If too little snuff back occurs, the materials may
drip out of the static mixer and affect dispense quantity.
It is most efficient to adjust the snuff back while material
is dispensing, but it can also be adjusted when there is
no air pressure in the system.
1.
or
2.
Select a small size shot.
3.
If a static mixer is not in place, install one, then
prime the machine. See
,
page 28.
4.
Place a waste container under static mixer.
5.
Press the Dispense Request button (
).
6.
Inspect the tip of the static mixer for dripping mate-
rial or for air bubbles traveling up the mixer.
7.
Perform another shot and, while dispensing, adjust
the snuff-back adjustment knob as follows.
•
If an air bubble is moving up the mixer, turn the
knob clockwise to decrease snuff back.
•
If material is hanging from the tip of the mixer,
turn the knob counterclockwise to increase
snuff back.
8.
Repeat step 7 until snuff back is adjusted as
desired.
Содержание PR70e
Страница 9: ...Component Identification 334135B 9...
Страница 12: ...Recommended Parts 12 334135B Mixers 1301 1303 1302 Assembly LC0061 Shown ti12442a...
Страница 19: ...Recommended Parts 334135B 19...
Страница 56: ...Schematics 56 334135B Schematics Electrical Schematics FIG 21 Electrical Schematic...
Страница 57: ...Schematics 334135B 57 FIG 22 Electrical Schematic...
Страница 59: ...Schematics 334135B 59...
Страница 67: ...Dimensions 334135B 67 Dimensions 25 1 in 65 cm 27 9 in 71 cm 9 0 in 23 cm 15 5 in 40 cm...
Страница 68: ...Dimensions 68 334135B...