Troubleshooting
334135B
39
LCM Error Codes
If an error condition exists, the front Panel LED will blink the number of times corresponding to the error code number,
pause, then repeat. After the user acknowledges the generated error screen, the error number will appear on the bot-
tom left-hand side of the main run screen, and the described blink sequence will continue. If more than one error is
present, all will be presented, separated by commas. When the condition is cleared, the corresponding error number
will be removed from the main run screen. If an error code is present, the machine will not dispense.
Code
Name
Type
Causes
Fixes
Trigger
Condition
E3
Improper
Machine Cali-
bration
Alarm
Machine has not been
calibrated or has been
calibrated incorrectly.
Perform pump position
entries in
. Retract posi-
tion must be less than
metering tube position, which
should be less than the fully
extend position.
When
requesting a
dispense
operation.
E4
Bad Linear
Position Sen-
sor
Alarm
1. Connection to position
sensor disconnected.
2. Power to position sen-
sor interrupted.
3. Bad position sensor.
1. Verify connections to the
sensor.
2. Verify proper readings from
sensor on setup screen 1.
3. Replace sensor
Invalid read-
ings from the
sensor.
E5
Stuck key
Alarm
1. Key is in an active
state.
2. Tactile switch on LCM
is shorted or broke.
Replace LCM Module.
If key is
detected to
be active for
more than 30
seconds.
Содержание PR70e
Страница 9: ...Component Identification 334135B 9...
Страница 12: ...Recommended Parts 12 334135B Mixers 1301 1303 1302 Assembly LC0061 Shown ti12442a...
Страница 19: ...Recommended Parts 334135B 19...
Страница 56: ...Schematics 56 334135B Schematics Electrical Schematics FIG 21 Electrical Schematic...
Страница 57: ...Schematics 334135B 57 FIG 22 Electrical Schematic...
Страница 59: ...Schematics 334135B 59...
Страница 67: ...Dimensions 334135B 67 Dimensions 25 1 in 65 cm 27 9 in 71 cm 9 0 in 23 cm 15 5 in 40 cm...
Страница 68: ...Dimensions 68 334135B...