Installation
8
309572M
Installation
Description
The heated hose maintains proper fluid tem-
perature while spraying.
Fluid hoses are marked with red tape for
ISO/hardener/minor volume side, blue tape for
RES/resin/major volume side. Fittings have dif-
ferent sized threads to prevent incorrect con-
nection, which can cause fluid crossover and
permanently damage the hose.
Hoses are 50 ft (15.2 m) or 25 ft (7.6 m) long.
The whip hose is 10 ft (3 m) long.
Set Transformer Wire Taps
Transformer tap wire connections vary
depending on proportioner and length of
heated hose. See proportioner operation man-
ual for further information. Some models are
automatic and have no user-set taps. Verify
that tap wire connections are correct.
* Length includes heated fluid hose and whip
hose.
WARNING
This hose must be used with an FTS and
cable to provide grounding. Read warnings,
page 6.
To heat the major volume hose only in a
wide ratio system, see 15F144 Hose
Wire Jumper, page 20.
Hose Length* ft (m)
Tap Terminal
Label (ft)
50 - 85 (15.2 - 25.9)
50
100 - 135 (30.5 - 41.1)
100
150 - 185 (48.7 - 56.4)
150
200 - 235 (60.1 - 71.6)
200
250 - 285 (76.2 - 86.9)
250
300 - 310 (91.4 - 94.5)
300
Содержание Power-Lock