background image

Warnings 

6

309572M

Warnings

Warning

Skin Injection Hazard
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may 
look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgi-
cal treatment.

Do not point the gun at anyone or at any part of the body.

Do not put your hand or fingers over the gun fluid nozzle.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Do not “blow back” fluid; this is not an air spray system.

Follow , page 22, when you stop spraying and before cleaning, checking, or servicing equip-
ment. 

Use lowest possible pressure when flushing, priming, or troubleshooting.

Engage spray gun piston safety lock when not spraying.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. High 
pressure hose cannot be recoupled; replace the entire hose.

Fire, Explosion, AND ELECTRIC SHOCK Hazard
Solvent and fumes in work area can ignite or explode. To help prevent fire, explosion, and elec-
tric shock:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (poten-
tial static arc). 

Do not plug or unplug power cords or turn lights on or off when flammable fumes are 
present.

Keep the work area free of debris, including solvent, rags, and gasoline.

Ground equipment and conductive objects. See Grounding in your proportioner manual.

Hold gun firmly to side of grounded pail when triggering into pail.

Use only grounded hoses.

If there is static sparking or you feel a shock, stop operation immediately. Do not use 
equipment until you identify and correct the problem.

Содержание Power-Lock

Страница 1: ...with plural component proportioners Not for use in explosive atmospheres See page 3 for Maximum Fluid Working Pressure 130 psi 0 9 MPa 9 bar Maximum Air Working Pressure 180 F 82 C Maximum Hose Operat...

Страница 2: ...nsor JIC to JIC fittings 17 Using 261670 Fluid Temperature Sensor JIC to NPT fittings 18 15F144 Hose Wire Jumper 20 Technical Data 23 Accessories 23 Scuff Guard 23 Warranty 24 Graco Phone Numbers 24 M...

Страница 3: ...5 2 5 5 6 6 2000 13 8 138 246076 F No FTS cable no scuff guard 1 2 13 50 15 2 8 8 10 10 2000 13 8 138 246678 F With FTS cable and scuff guard 3 8 10 50 15 2 5 5 6 6 2000 13 8 138 246052 F With FTS cab...

Страница 4: ...47 8 8 10 10 2000 13 8 138 50 15 2 1 4 6 No FTS cable no scuff guard 1225B PL 246074 5 5 6 6 2000 13 8 138 50 15 2 3 8 10 No FTS cable no scuff guard 1200B PL 246075 5 5 6 6 2000 13 8 138 50 15 2 1 2...

Страница 5: ...PL 246063 8 8 10 10 2000 13 8 138 50 15 2 1 2 13 Single hose B RES side 5226C 50 PL 246064 8 8 10 10 2000 13 8 138 25 7 6 1 4 6 Single hose A ISO side 1265A PL 246065 5 5 6 6 2000 13 8 138 25 7 6 1 4...

Страница 6: ...re operating the equipment Check hoses tubes and couplings daily Replace worn or damaged parts immediately High pressure hose cannot be recoupled replace the entire hose Fire Explosion AND ELECTRIC SH...

Страница 7: ...y with all applicable safety regulations Burn Hazard This equipment is used with heated fluid which can cause equipment surfaces to become very hot To avoid severe burns Do not touch hot fluid or equi...

Страница 8: ...re Taps Transformer tap wire connections vary depending on proportioner and length of heated hose See proportioner operation man ual for further information Some models are automatic and have no user...

Страница 9: ...e ends to the correct length See Strip Length Gauge for correct length WARNING Read warnings pages 6 and 7 FIG 1 FIG 2 Do not connect the main air supply to the air hose at this time Common insulated...

Страница 10: ...t See FIG 7 b Thread in setscrew and use hex wrench to torque setscrew to 60 in lbs 6 78 N m c Insert remaining wire from pair into con nector ensure proper insertion depth Thread setscrew and torque...

Страница 11: ...m of wire on each side of con nector is wrapped 6 Connect cables F Slide insulator sleeves over connection Leave slack G in cables as stress relief to prevent cable failure 7 Repeat for additional hos...

Страница 12: ...air hose C to whip air hose L 7 Connect hose assembly cable F to FTS cable R Slide insulator sleeves S over connection Leave slack G in cables as stress relief to prevent cable failure 8 See Check Hos...

Страница 13: ...o page 9 for instructions 5 Connect hose assembly cable F to FTS cable R Slide insulator sleeves S over connection Leave slack G in cables as stress relief to prevent cable failure 6 See Check Hoses f...

Страница 14: ...manual for priming instructions After all lines are free of air check for leaks If there are leaks relieve pressure as instructed in proportioner manual Tighten connections then pressurize again to e...

Страница 15: ...ap all electrical connections and cable connections with electrical tape to protect them from pulling apart and abra sion 3 Install protective cover see Accessories page 23 or wrap hose bundle with du...

Страница 16: ...Before disconnecting or repairing hoses relieve all fluid pressure and shut off electri cal power to proportioner See proportioner operation manual 2 Be sure fluid is cool before disconnecting hoses W...

Страница 17: ...15C624 HOSE air 25 ft 7 6 m 1 4 15B296 CABLE FTS 50 ft 15 2 m 1 15C626 CABLE FTS 25 ft 7 6 m 1 5 261669 FLUID TEMPERATURE SENSOR includes items 5a 5d 1 5a 117455 NIPPLE 1 4 npt m x 5 JIC m 1 5b 117595...

Страница 18: ...hardener 1 2 chart 2 page 19 HOSE resin 1 4 15B296 CABLE FTS 50 ft 15 2 m 1 15C626 CABLE FTS 25 ft 7 6 m 1 5 261670 FLUID TEMPERATURE SENSOR includes items 5a 5d 1 5a 156823 SWIVEL 1 4 npt m x f 1 5b...

Страница 19: ...n mm Length ft m Maximum Fluid Pressure psi MPa bar 246059 1 4 6 50 15 2 2000 13 8 138 246061 3 8 10 50 15 2 2000 13 8 138 246063 1 2 13 50 15 2 2000 13 8 138 246065 1 4 6 25 7 6 2000 13 8 138 246094...

Страница 20: ...Hoses page 9 6 Install one Power Lock connector 100a between wires see page 9 Ref Part Description Qty 100 15F144 JUMPER hose wire includes two 117789 electrical connec tors 50 ft 15 2 m long 1 101 c...

Страница 21: ...aps using the follow ing table Transformer tap wire connections vary depending on length of heated hose See proportioner operation manual for fur ther information Verify that tap wire con nections are...

Страница 22: ...Parts 22 309572M...

Страница 23: ...eel Total Heating Load 2 hoses 1 4 diameter 11 watts foot 36 watts meter 3 8 diameter 13 watts foot 43 watts meter 1 2 diameter 15 watts foot 49 watts meter Part Description 246077 10 ft 3 m braided p...

Страница 24: ...kmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...

Отзывы: