23
307982
Technical Data -- 25:1 Bulldog Pump
Category
Data
Maximum working pressure
17.5 MPa, 175 bar (2500 psi)
Air operating range
.07--0.7 MPa, 0.7--7 bar (10--100 psi)
Pump cycles per 3.8 liters (per 1 gallon)
20
Maximum recommended pump speed
for intermittent operation
60 cycles per minute
Air inlet size
3/4 npsm(f)
Fluid outlet size
1 in. npt(f)
Wetted parts
17--4 PH and 304 Grades of Stainless Steel, Chrome--plated Stainless
Steel, Zinc--plated Carbon Steel, Ultra--high Molecular Weight
Polyethylene, Tungsten Carbide, PTFE and FKM
Stroke length
120 mm (4.75 in.)
Pump Performance Chart
To find outlet pressure (bar/psi) at a specific delivery (liter/
min--GPM) and operating air pressure (bar/psi):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with selected fluid
outlet pressure curve. Curve slopes from left to right.
Follow left to scale and read outlet pressure.
To find pump air consumption (m
3
/min--CFM) specific delivery
(liter/min--GPM) and operating air pressure (bar/psi):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with selected air
consumption curve. Curve slopes from right to left.
Follow right to scale and read air consumption. Follow
left to scale and read outlet pressure.