background image

Setup 

4

308667U

Setup

1. Before adding any fluid to the drum, select the evac-

uation method you will use to empty fluid from the 
drum when it is full. 

For evacuation systems, be sure the drain plug (12) 
is installed (also see instruction manual 308719.)

For gravity fed systems, remove drain plug (12) and 
install drain valve (25).

NOTE: 

In F

IG

. 1 the drain valve (25) is shown in the 

closed position. To open it, rotate the handle so it points 
away from the drum.

2. The strainer (2f) is shipped loose and must be 

installed in funnel assembly (2) prior to use (F

IG

. 2).

Positioning the Collection Container

Guide the collection container to the drain location.

Use the front handle (a) to move the collection 
container. Pivoting casters (b) are located on 
the front of the container to help make it easier 
to maneuver into the correct draining position.

NOTICE

Install a gravity drain valve to prevent spilling when not 
using a receiver evacuation system. 

F

IG

. 1

F

IG

. 2

25

12

2f

2

NOTICE

Do not attempt to move the collection container with 
the funnel assembly (2) raised or after you have started 
any drain procedure. 

• Lowering the funnel assembly (2) until it meets the 

funnel collar (6), lowers the center of gravity and 
reduces the possibility of the unit tipping. 

• Moving the collection container before completing 

any drain procedure could result in tipping and 
cause accidental fluid spills.

F

IG

. 3

b

a

Содержание Oil King

Страница 1: ...Models 238866 Series D Used Oil Receiver 248632 Series D Used Anti Freeze Receiver 243650 Series A Funnel Kit Important Safety Instructions Read all warnings and instructions in this manual Save these...

Страница 2: ...ow the Pressure Relief Procedure when equipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter...

Страница 3: ...essure Relief Procedure and disconnect all power sources PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating servicing or when in the operating area of the equi...

Страница 4: ...uide the collection container to the drain location Use the front handle a to move the collection container Pivoting casters b are located on the front of the container to help make it easier to maneu...

Страница 5: ...empty contents into an approved disposal container Always dispose of used fluids according to local state and national codes applicable to the discarded fluid Read fluid and solvent manufacturer s war...

Страница 6: ...t 2 19 BOLT hex head 5 16 18 x 3 4 inch 8 20 100214 WASHER lock 5 16 inch 8 21 191824 WASHER spacer 0 66 inch I D x 0 25 inch thick 2 22 111841 WASHER plain 5 8 inch 4 25 113895 VALVE drain 3 4 inch 1...

Страница 7: ...Parts 308667U 7...

Страница 8: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANT...

Отзывы: