Setup
4
308667U
Setup
1. Before adding any fluid to the drum, select the evac-
uation method you will use to empty fluid from the
drum when it is full.
•
For evacuation systems, be sure the drain plug (12)
is installed (also see instruction manual 308719.)
•
For gravity fed systems, remove drain plug (12) and
install drain valve (25).
NOTE:
In F
IG
. 1 the drain valve (25) is shown in the
closed position. To open it, rotate the handle so it points
away from the drum.
2. The strainer (2f) is shipped loose and must be
installed in funnel assembly (2) prior to use (F
. 2).
Positioning the Collection Container
Guide the collection container to the drain location.
•
Use the front handle (a) to move the collection
container. Pivoting casters (b) are located on
the front of the container to help make it easier
to maneuver into the correct draining position.
NOTICE
Install a gravity drain valve to prevent spilling when not
using a receiver evacuation system.
F
IG
. 1
F
IG
. 2
25
12
2f
2
NOTICE
Do not attempt to move the collection container with
the funnel assembly (2) raised or after you have started
any drain procedure.
• Lowering the funnel assembly (2) until it meets the
funnel collar (6), lowers the center of gravity and
reduces the possibility of the unit tipping.
• Moving the collection container before completing
any drain procedure could result in tipping and
cause accidental fluid spills.
F
IG
. 3
b
a
Содержание Oil King