DataTrak Operation
14
311238ZAM
Replace the DataTrak Module
Battery or Fuse
1. Remove two screws (135). Carefully slide the Data-
Trak module (131) out of the housing (132). See
F
IG
. 4.
2. Disconnect the runaway solenoid and sensor cables
from the module board. See F
IG
. 5.
3. Take the DataTrak module (131) to a non-hazard-
ous location.
4.
To replace the battery,
disconnect the used bat-
tery and replace with an approved battery.
5.
To replace the fuse (131a):
a. Remove the screw, metal strap, and plastic
holder.
b. Pull the fuse away from the board.
c. Replace with a new fuse (131a).
* F
IG
. 4 shows where to find the Series letter.
To reduce the risk of fire and explosion, the battery
and fuse must be replaced in a non-hazardous loca-
tion.
Use only an approved replacement battery, shown in
Table 2, and an approved fuse, shown in Table 3.
Use of an unapproved battery or fuse will void
Graco’s warranty and Intertek and Ex approvals.
F
IG
. 4. Remove DataTrak Module
132
131
135
TI8216c
Series
Letter
Use only a Graco-approved replacement fuse (131a).
Table 2: Approved Batteries
Energizer alkaline # 522
Varta alkaline # 4922
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Table 3: Approved Fuses
Series*
Fuse Required
A
NXT413
B and later
24V216
F
IG
. 5. DataTrak Battery and Fuse Location
Solenoid Cable Connection
Battery
Fuse (131a)
Sensor Cable Connection
TI7757a