DataTrak Controls and Indicators
10
311238ZAM
DataTrak Controls and Indicators
Key for F
IG
. 3
T
Runaway Limit, in cycles per minute (user settable;
00=OFF)
U
Lower Displacement (user settable)
V
Flow Rate Units (user settable to
gpm [US],
gpm [Imperial], oz/min [US], oz/min [Imperial], l/min, or
cc/min)
W LED (fault indicator when lit)
X
Diagnostic Reference Card (see T
ABLE
1, page 13)
Y
Display
PF Prime/Flush Key (Enables Prime/Flush mode. While in
Prime/Flush mode, runaway protection is disabled and
the batch totalizer [BT] will not count.)
RK Reset Key (Resets faults. Press and hold for 3 seconds to
clear the batch totalizer.)
CF Cycle/Flow Rate
BT Batch Totalizer
GT Grand Totalizer
RT Runaway Toggle (enable/disable)
UT E1 Toggle
DT E2 Toggle
ST E5 Toggle
DataTrak is included with certain models. See page 3 for a list of models featuring DataTrak.
It is recommended that a 3/4 in. air line lubricator be used with DataTrak models.
For remote DataTrak models, see your system operation manuals.
To prevent damage to the soft key buttons, do not press the buttons with sharp objects such as pens, plastic
cards, or fingernails.
/min,
F
IG
. 3. DataTrak Controls and Indicators
X
W
Y; See Details at right.
CF
BT
GT
V
RT
T
PF
RK
U
UT
DT
ST
Run Mode
Setup Mode
TI8215a
TI8622b
TI8623b
RK
PF