Advanced Troubleshooting
26
332697C
Motor runs and pump cycles, but
pressure does not build up.
Intake valve or outlet valve is not
seating properly.
Remove and clean inlet valves and outlet valves.
Replace if necessary. See
List of Kits
, page 30.
Pump packings are worn or
damaged.
Check for leaking around pump.
A60:
Replace pump packings. See
List of Kits
,
A20, A30, A45:
Replace complete pump. See
List
of Kits
, page 30.
Specific Problem
Cause
Solution
Excessive Pressure Build Up
Specific Problem
Cause
Solution
Prime/Spray Valve actuates
automatically, relieving pressure
through drain tube.
Pressure control switch has
pinched wires or switch is worn.
Replace pressure control switch using
Pressure
Control Switch Kit
, page 28.
Water or paint entered pressure
control switch or shorted control
board.
Use
Pressure Control Switch Kit
, to replace
switch. See
List of Kits
, page 30.
Control board failed.
See
Control Board Diagnostics
, page 29. Replace
damaged control board using
Control Board Kit.
See
List of Kits
, page 30.