Clean-up
20
3A4587B Operation, Repair, Parts
12. Raise siphon tube above flushing fluid and run striper
for 15 to 30 seconds to drain fluid.
13. Turn pump switch
OFF
. Turn engine
OFF
.
14. Close prime valve. Trigger gun into flushing pail to
purge fluid from hose. Open prime valve.
15. Install filter into filter bowl. Make sure plastic center
tube is tightened securely.
16. Clean Rac Tip, Rac Guard and gasket with a soft
bristle brush to prevent part failure due to dried
materials. Assemble parts and attach loosely onto
gun.
17. Wipe striper, hose and gun with a rag soaked in
water or mineral spirits.
NOTICE
Do not run pump without fluid flow. Damage to
packings can occur.
NOTICE
If flushing with water, do not leave water in sprayer for
extended periods. Flush again with Pump Armor and
leave protective coating in the sprayer to prevent freez-
ing or corrosion and to increase sprayer life.
ti30119a
ti27504a
ti30489a
ti30121a
ti30310a
ti30123a