background image

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The

exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific

risks. When these symbols appear in the body of this manual or on warning labels, refer back to these

Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout

the body of this manual where applicable.

WARNING

EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated

system component. See Technical Data in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data

in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete

information about your material, request MSDS from distributor or retailer.

• Do not leave the workarea while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Checkequipment daily. Repair or replace worn or damaged parts immediately with genuine

manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals

and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from workarea.
• Comply with all applicable safety regulations.

Related Manuals

Manual

Description

333347

InvisiPac™ HM25 and

HM50 Tank-Free™ Hot

Melt Delivery System

Models

Table 1 AFS Models

Model No. For use on InvisiPac Systems

HM50: 24T918, 24T919, 24T920,

24V201, 24V202, 24V203

17D749

HM25: 24V423, 24V424, 24V425,

24V429, 24V430, 24V431

2

334629A

Содержание InvisiPac AFS 17D749

Страница 1: ...es to the Invisipac Hot Melt Delivery System Important Safety Instructions Read all warnings and instructions in this manual and in related manuals Save these instructions Kit No 17D749 See model numb...

Страница 2: ...ur material request MSDS from distributor or retailer Do not leave the work area while equipment is energized or under pressure Turn off all equipment and follow the Pressure Relief Procedure when equ...

Страница 3: ...mponent Identification Component Identi cation Hopper A Wand B Hopper Cover C Hopper D Pilot Valve E Hopper Shaker Wand A Wand B Wand Shaker C Wand Holder D Vacuum Inlet E Air Assist Injector 334629A...

Страница 4: ...t White D To Hopper Shaker Inlet Black E Hopper Shaker Inlet Black F AFS Assist Air Line Air IN Gray G InvisiPac Feed Air IN Black Wand Pneumatic Connections A Wand Shaker Inlet Black B Air Assist Inj...

Страница 5: ...of the InvisiPac Connect the other end of black airline to the outside of the feed container tting G See Fig 2 Figure 2 3 Remove packing material from new container and feed wand inside the container...

Страница 6: ...eed container F See Fig 6 9 Lift and rotate the lid to ll container with hot melt adhesive Figure 7 10 Turn on InvisiPac and open air supply ball valve to unit Check all ttings to ensure there are no...

Страница 7: ...with optional lter hopper cover kit 17D747 1 Unscrew the knurled knob on top of the air lter unit Pull cover off the lter remove lter and replace with new lter 2 Place cover back on top of the air lte...

Страница 8: ...r Assist Injector Kit 24X330 Repair kit for replacing the air assist on the AFS wand Accessories AFS Filtered Hopper Cover Kit 17D747 Hopper upgrade for dirty environments The ltered hopper cover seal...

Страница 9: ...sfer Operating Pneumatic Pressure Range 60 100 psi 420 690 kPa 4 2 6 9 bar Vacuum Transfer Air Consumption at 60 psi Feed Regulator 80 psi Air Inlet 420 kPa 4 2 bar Feed Regulator 550 kPa 5 5 bar Air...

Страница 10: ...s lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale GRAC...