Installation
6
332590A
12. On the left wall inside the Reactor cabinet, locate
and identify whether your system uses the tempera-
ture control module or temperature control board.
See F
. 5 for an example of each.
13. For models with temperature control board, connect
TEMP cable (T) to J8 on board. See F
. 4.
14. For models with temperature control module,
remove cover kit (AA) then connect TEMP cable to
J8 on module. Re-install cover kit (AA). See F
NOTE: The cap on the HEAT cable plug may prevent
plug from being fully inserted into the temperature con-
trol module. Press plug to the right then press plug the
rest of the way into place.
15. Connect PUMP cable (P) to J12 on motor control
board.
16. Secure power cables away from hose transformer
hot surfaces.
17. Re-install Reactor cabinet front access door.
F
IG
. 4: Temperature Control Board
F
IG
. 5: Temperature Control Module
J8
ti21803a
T
J8
AA
ti21804a
F
IG
. 6: Motor Control Board
J12
J12
Models E-30 and E-XP2
Models E-20 and E-XP1
Hydraulic Reactor Models
J12
ti21813a
ti21805a
ti21806a
P
P
P