background image

6

306926

Operation

Pressure Relief Procedure

WARNING

INJECTION HAZARD

Fluid under high pressure can be in-
jected through the skin and cause seri-
ous injury. To reduce the risk of an injury

from injection, splashing fluid, or moving parts, fol-
low the 

Pressure Relief Procedure

 whenever you:

D

are instructed to relieve the pressure,

D

stop spraying,

D

check or service any of the system equipment,

D

or install or clean the spray tips.

1.

Lock the gun trigger safety.

2.

Close the air regulator.

3.

Close the bleed-type master air valve (E).

4.

Unlock the gun trigger safety.

5.

Hold a metal part of the gun firmly to the side of a
grounded metal pail, and trigger the gun to relieve
pressure.

6.

Lock the gun trigger safety.

7.

Open the drain valve (required in your system),
having a container ready to catch the drainage.

8.

Leave the drain valve open until you are ready to
spray again.

If you suspect that the spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following the steps above, very slowly loosen the
tip guard retaining nut or hose end coupling and relieve
pressure gradually. Then, loosen completely. Clear the
tip or hose obstruction.

Pump Operation

Prepare the cleaning solution according to the
manufacturer’s instructions. For your own safety, be
sure to observe all warnings. If you are using pow-
dered cleaners, mix them thoroughly in a separate pail
before adding them to a supply drum. Undissolved
powders are extremely abrasive and may damage
pump parts.

WARNING

Wear appropriate protective clothing, such as
waterproof outerwear and eye goggles, according
to the cleaner manufacturer’s recommendations.
Cleaning chemicals may be toxic, and cause
serious irritation to your eyes or skin.

See Fig. 2. To start the pump, close the bleed–type
master air valve (E), close the air regulator (24) by
turning the T-handle all the counterclockwise until the
spring tension is relieved. Open the shutoff valve, hold
a metal part of the gun firmly to the side of a grounded
metal pail, trigger the gun, and slowly open the regula-
tor until fluid comes from the gun. Release the trigger;
the pump will stall against pressure.

When supplied with an adequate air pressure and
volume, the pump will start and stop as the gun is
opened and closed.

Use the air regulator (24) to control pump speed and
fluid pressure. Always use the lowest pressure neces-
sary to get the desired result. Higher pressures will
waste the material and cause early spray tip and pump
wear.

Содержание Hydra-Clean 226-314 F Series F

Страница 1: ...eanR Pressure Washer 1000 psi 6 9 MPa 69 bar Maximum Working Pressure Model 226314 Series G 06648B CAUTION The Graco warranty will not apply if cleaning solutions other than those recommended by Graco...

Страница 2: ...tended purpose If you are unsure about usage call your Graco distributor D Do not alter or modify this equipment Use only Graco parts and accessories D Check equipment daily Repair or replace worn or...

Страница 3: ...n flames or sparks can cause a hazardous condition and re sult in a fire or explosion and serious injury D Ground the equipment and the object being sprayed Refer to Grounding on page 4 D If there is...

Страница 4: ...e to a true earth ground Order Part No 222011 Ground Wire and Clamp Fig 1 TI1052 Y Z 3 Air and fluid hoses use only electrically conductive hoses 4 Air compressor follow manufacturer s recommen dation...

Страница 5: ...nother spray hose Connect the spray gun 35 to the hose 22 Use thread sealant on the male threads Fill the displacement pump wet cup C 1 2 full with Throat Seal Liquid or a compatible solvent Refer to...

Страница 6: ...ear the tip or hose obstruction Pump Operation Prepare the cleaning solution according to the manufacturer s instructions For your own safety be sure to observe all warnings If you are using pow dered...

Страница 7: ...better check with your cleaner manufacturer After all dirt is cleaned off rinse all the solution off with clean cold water Relieve the pressure whenever you stop spraying Always stop the pump at the...

Страница 8: ...ilter Clean Exhausted cleaning solution supply Refill Worn or damaged pump parts See manual 306818 or 306821 Valve will not stop fluid spray Incorrect valve adjustment Adjust see manual 307010 y Obstr...

Страница 9: ...psi 2 1 MPa 21 bar 7 3 28 3 7 3 28 3 510 psi 3 5 MPa 35 bar 8 5 32 2 95 2 66 700 psi 4 8 MPa 48 bar KEY TO PERFORMANCE CHART GPM Gallons Per Minute CFM Cubic Feet Per Minute PSI Pounds Per Square Inch...

Страница 10: ...10 306926 Parts 7663B 47 42 21 24 1e 1f 1g Detail B 23 18 15 19 26 17 28 29 22 Detail A 10 16 Detail B Detail A 2 30 33 32 34 1 35 31 46 48 1a 1b 1c 1d...

Страница 11: ...2 npt m x 1 in npt f 1 21 238374 HOSE coupled 1 22 205753 HOSE fluid cpld 3 8 npt m 40 ft 12 2 m lg Buna N 3 8 in ID 1 23 205770 HANGER pipe 1 24 244720 AIR REGULATOR See manual 309341 for parts 1 26...

Страница 12: ...orth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or co...