308986
17
Installation – Optional Fluid Heaters
IN
OUT
RES
HEATER
IN
OUT
HARD
HEATER
RES
HARD
RES
RES
HARD
RES
HARD
Fig. 12
17A
17B
202A
202B
203B
203A
23
204B
205A
FA
FB
02894
Three Displacement Pump Models
1.
Loosen the swivel of the unions (17A, 17B) to
remove the elbow (16A, 16B) on each side of the
mixer manifold (23). Turn the unions (17A, 17B) so
the outlet faces up. See Figs. 12 and 13.
2.
Connect a new hardener fluid hose (204B)
between the union (17B) and the swivel (203B) at
the heater inlet. See Fig. 12.
3.
Install another hardener fluid hose (FB) between
the heater outlet elbow (202B) and the hardener
side of the mixer manifold (23). See Fig. 12.
4.
Repeat Steps 1 to 3 for the resin side of the
system (the “A” side).
02892A
Fig. 13
16B
16A
17B
17A
23
RES
HARD
Содержание HYDRA-CAT FIXED RATIO
Страница 38: ...38 308986 Notes...
Страница 39: ...308986 39 Notes...