![background image](http://html1.mh-extra.com/html/graco/hydra-cat-fixed-ratio/hydra-cat-fixed-ratio_instructions-parts-list-manual_2253196015.webp)
308986
15
Installation – Optional Fluid Heaters
Fig. 9
201
202
203
204
10
201a
201b
IN
OUT
02913A
WARNING
INJECTION HAZARD
To reduce the risk of serious injury,
follow the
Pressure Relief Procedure
on page 23 before installing the heaters.
All Models
1.
See Fig. 9. Mount a heater to each side of the
mounting bracket using the three screws (201a)
and lockwashers (201b) supplied with each heater.
2.
Connect a swivel union (202) to the outlet of each
heater.
3.
Connect a swivel union (203) to the inlet of each
heater.
CAUTION
Use heaters for unmixed material only. Heating
mixed material will cause the mixture to solidify in the
heater making the heater unusable.
Heaters can be used to heat separate material
components before mixing. Material can also be
heated in a circualtion feed system or between the
outlet of the material pump and the mix manifold.
Содержание HYDRA-CAT FIXED RATIO
Страница 38: ...38 308986 Notes...