Operation
Operation
Operation
Tighten
Tighten
Tighten Fasteners
Fasteners
Fasteners
Before mounting and using the pump for the first time,
check and retorque all external fasteners. Follow
, or see the torque
tag on your pump. After the first day of operation,
retorque the fasteners.
Initial
Initial
Initial Configuration
Configuration
Configuration (AC
(AC
(AC with
with
with VFD)
VFD)
VFD)
Configure the VFD according to the motor nameplate
information.
Flush
Flush
Flush the
the
the Pump
Pump
Pump Before
Before
Before First
First
First Use
Use
Use
The pump was tested in water. If water could
contaminate the fluid you are pumping, flush the
pump thoroughly with a compatible solvent. See
.
Transfer
Transfer
Transfer Mode
Mode
Mode Vs.
Vs.
Vs. Low
Low
Low Pulsation
Pulsation
Pulsation
Mode
Mode
Mode
When the air pressure is at least 10 psi higher than
the desired outlet pressure, the pump is in Transfer
Mode and no pulsation damping is occurring. To
reduce outlet pulsation, start by setting the air
pressure
equal
to the desired outlet fluid pressure.
Continue to adjust the air pressure relative to the
outlet fluid pressure. Lower relative air pressures
produce more pulsation damping. Higher relative air
pressures produce better pump efficiency.
Start
Start
Start and
and
and Adjust
Adjust
Adjust the
the
the Pump
Pump
Pump
1.
Be sure the pump is properly grounded. See
2.
Check fittings to be sure they are tight. Use a
compatible liquid thread sealant on male threads.
Tighten fluid inlet and fluid outlet fittings securely.
3.
Place the suction tube (if used) in fluid to be
pumped.
NOTE:
NOTE:
NOTE: If fluid inlet pressure to the pump is more
than 25% of outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation.
NOTICE
NOTICE
NOTICE
Excessive fluid inlet pressure can reduce
diaphragm life.
4.
Place the end of the fluid hose into an appropriate
container.
5.
Close the fluid drain valve.
6.
Turn the air regulator knob to match the desired
fluid stall pressure. Open all bleed-type master
air valves.
7.
If the fluid hose has a dispensing device, hold it
open. Be sure all fluid shutoff valves are open.
8.
Set the desired frequency on the VFD.
9.
Press the start (run) button on the VFD.
10. If you are flushing, run the pump long enough to
thoroughly clean the pump and hoses.
3A4068H
19
Содержание Husky 2150e
Страница 29: ...Dimensions Dimensions Dimensions Dimensions Aluminum or cast iron pump with compressor 3A4068H 29 ...
Страница 30: ...Dimensions Aluminum or cast iron pump without compressor 30 3A4068H ...
Страница 33: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump with compressor 3A4068H 33 ...
Страница 34: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump without compressor 34 3A4068H ...
Страница 36: ...Dimensions Stainless steel pump with compressor Stainless steel pump without compressor 36 3A4068H ...