Maintenance
Maintenance
Maintenance
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
Maintenance
Maintenance
Maintenance Schedule
Schedule
Schedule
Establish a preventive maintenance schedule
based on the pump’s service history. Scheduled
maintenance is especially important to prevent spills
or leakage due to diaphragm failure.
Lubrication
Lubrication
Lubrication
The pump is lubricated at the factory. It is designed
to require no further lubrication for the life of the
bearings. There is no need to add an inline lubricator
under normal operating conditions.
Tighten
Tighten
Tighten Threaded
Threaded
Threaded Connections
Connections
Connections
Before each use, check all hoses for wear or damage
and replace as necessary. Check to be sure all
threaded connections are tight and leak-free. Check
mounting bolts. Check fasteners. Tighten or retorque
as necessary. Although pump use varies, a general
guideline is to retorque fasteners every two months.
See
Flushing
Flushing
Flushing and
and
and Storage
Storage
Storage
To avoid injury from fire, explosion, or electric
shock, always ground equipment and waste
container. To avoid static sparking and injury from
splashing, always flush at the lowest possible
pressure..
• Flush before first use.
• Flush at the end of the day, before storing, and
before repairing equipment.
• Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
• Flush with a fluid that is compatible with the fluid
being dispensed and the equipment wetted parts.
• Always flush the pump and relieve the pressure
before storing it for any length of time.
NOTICE
NOTICE
NOTICE
Flush the pump often enough to prevent the
fluid you are pumping from drying or freezing in
the pump and damaging it. Store the pump at
32°F (0°C) or higher. Exposure to extreme low
temperatures may result in damage to plastic parts.
22
3A4068H
Содержание Husky 2150e
Страница 29: ...Dimensions Dimensions Dimensions Dimensions Aluminum or cast iron pump with compressor 3A4068H 29 ...
Страница 30: ...Dimensions Aluminum or cast iron pump without compressor 30 3A4068H ...
Страница 33: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump with compressor 3A4068H 33 ...
Страница 34: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump without compressor 34 3A4068H ...
Страница 36: ...Dimensions Stainless steel pump with compressor Stainless steel pump without compressor 36 3A4068H ...