Performance Chart - 1040
309528L
33
Performance Chart - 1040
Test Conditions: Pump tested in water with inlet submerged
Fluid Pressure Curves
A at 120 psi (0.7 MPa, 7 bar) air pressure
B at 100 psi (0.7 MPa, 7 bar) air pressure
C at 70 psi (0.48 MPa, 4.8 bar) air pressure
D at 40 psi (0.28 MPa, 2.8 bar) air pressure
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.
Air Consumption Curves
A at 120 psi (0.7 MPa, 7 bar) air pressure
B at 100 psi (0.7 MPa, 7 bar) air pressure
C at 70 psi (0.48 MPa, 4.8 bar) air pressure
D at 40 psi (0.28 MPa, 2.8 bar) air pressure
To find Pump Air Pressure
(scfm or m
3
/min) at a specific fluid flow (gpm/lpm)
and operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected
air consumption curve.
3. Follow left to scale to read fluid outlet pressure.