308–044 5
Installation
Connect the Fluid Line
1. Before connecting the fluid line (B), blow it out with
air and flush it with solvent. Use solvent which is
compatible with the fluid to be sprayed.
2. Install a fluid regulator (K) on the fluid line (B) to
control fluid pressure to the gun.
3. Connect the fluid line to the 3/8–18 npsm
(R 3/8–19) gun fluid inlet.
Connect the Air Lines
1. Install an air filter (C) to provide a clean, dry air
supply to the gun. Dirt and moisture in the air line
can affect the appearance of your finished work-
piece.
2. Install a normally closed, 3-way air solenoid valve
(D) and air shut-off valve (N) in the cylinder air
supply line (E). Connect an air hose from the air
shut-off valve to the 1/4–18 npsm (R 1/4–19) gun
air inlet marked CYL.
3. Connect an atomizing air supply line (F) to the
1/4–18 npsm (R 1/4–19) gun air inlet marked
ATOM.
4. Install separate air regulators (G) to control atom-
izing air and cylinder air.
Recommended Hose Sizes
(General Purpose)
Fluid Hose
Air Hose
Length Needed
ID
Length Needed
ID
0–35 ft.
(0–11 m)
3/8 in.
0–100 ft.
(0–30 m)
5/16
in.
35–100 ft.
(11–30 m)
1/2 in.
100–200 ft.
(30–60 m)
3/8 in.
100–200 ft.
(30–60 m)
3/4 in.