Component Identification
3A2960A
3
Component Identification
Keypad, Display, and Icons
Pump ON LEDs (A, B, C)
A
Pressure Control LED: In RUN MODE illuminates
indicating function mode that is currently running.
B
Cycle Control LED: In RUN MODE illuminates
indicating function mode that is currently running.
C
Time Control LED: In RUN MODE illuminates
indicating function mode that is currently running.
Pump OFF LED (D)
•
In RUN MODE this LED illuminates when in the
OFF or RESET portion of the RUN CYCLE.
Display (E)
•
A blinking field on the display indicates the controller
is in SETUP MODE.
•
In RUN MODE numbers on the display will not blink.
Alarm LED (F)
Illuminates when any alarm is detected. When an alarm
is active an error code displays and an audible alarm
also sounds.
RIGHT Direction Arrow / MANUAL RUN /
ENTER (G)
•
In SETUP MODE, saves entry, moves cursor in
display one field to the right or to the next setup
step.
•
In RUN MODE activates the pump for one com-
plete ON cycle if actuated during the OFF por-
tion of the RUN cycle.
UP and DOWN Direction Arrows (H)
•
Press and hold both the UP and DOWN Arrow
keys together for 3 seconds to enter SETUP
MODE.
•
In SETUP MODE increase or decrease number
values associated with the various RUN
MODES.
LEFT Direction Arrow / RESET (J)
•
In SETUP MODE moves cursor in display one
field to the left.
•
In RUN MODE, Pressing RESET starts a PUMP
OFF cycle.
•
In ALARM MODE, Press once to clear buzzer;
Press and hold for 3 seconds to clear warning
and switch controller to OFF MODE.
NOTICE
To prevent damage to soft key buttons, do not press
the buttons with sharp objects such as pens, plastic
cards, or fingernails.
F
IG
. 1
ON
OFF
HH
MM
SS
##
!
J
D
F
A
B
C
E
H
G