Setup
20
332291G
Models without a follower plate:
1.
Connect fill hose to inlet fitting (F
IG
. 19).
2.
For higher viscosity fluids, start pump to rotate stir-
ring paddle during fill to prevent air pockets from
forming in grease. Do not exceed 30 minutes run
time.
For models using an external controller, start pump
operation per your controller specifications.
3.
Fill reservoir with NLGI grease.
NOTE:
Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
4.
Remove fill hose.
Models with a follower plate:
1.
Connect fill hose to inlet fitting (F
IG
. 19).
2.
For higher viscosity fluids, start pump to rotate stir-
ring paddle during fill to prevent air pockets from
forming in grease. Do not exceed 30 minutes run
time.
For models using an external controller, start pump
operation per your controller specifications.
3.
Fill reservoir with grease until seal of follower plate
breaches the vent hole (F
IG
. 20) and the majority of
air is expelled from the reservoir.
NOTE:
Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
4.
Remove fill hose.
Changing Greases
When changing greases, always use compatible fluids
or greases.
5.
Turn off the air supply (H) to refill pump (F).
6.
Relieve remote filling station pump pressure using
the following Remote Filling Station Pressure Relief
procedure.
F
IG
. 19
D
F
IG
. 20
vent hole