Setup
24
332291G
Priming
NOTE:
It is not necessary to prime pump every time
pump is filled with lubricant.
Pump only requires priming the first time it is used or if it
is allowed to run dry.
1.
Loosen pump element fitting (F
IG
. 26).
NOTE:
When loosening pump element fitting, do NOT
loosen
pump element
. Loosening pump element will
change the output volume
2.
Only run pump until air-free lubricant is dispensed
out of element fitting (F
IG
. 27).
3.
Tighten pump element fitting using two wrenches
working in opposite directions (F
IG
. 26).
F
IG
. 26
F