Warnings 

4

332255A

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a 
serious injury that can result in amputation. 

Get immediate surgical treatment.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the 

Pressure Relief Procedure

 when you stop spraying and before cleaning, checking, or servicing equip-

ment. 

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZAR

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See 

Technical Data

 in all equipment manuals.

Use fluid and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manu-
als. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS 
from distributor or retailer.

Do not leave the work area while equipment is energized or under pressure. 

Turn off all equipment and follow the 

Pressure Relief Procedure 

when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replace-
ment parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

PRESSURIZED ALUMINUM PARTS HAZARD

Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and 
equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.

Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing 
such solvents.

Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for 
compatibility.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.

Read MSDSs to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing 
loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

WARNING

WARNING

WARNING

WARNING

Содержание FT600 278680

Страница 1: ...the application of architectural paints and coatings For professional use only Model 278680 3300 psi 227 bar 22 7 MPa Maximum Working Pressure IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instr...

Страница 2: ...Requirements 6 Extension Cords 6 Pails 7 Pressure Relief Procedure 8 Setup 9 Startup 10 Tip and Guard Assembly 11 Spraying 11 Clearing Clog 12 Cleanup 13 Digital Display 15 Main Menu Operation 16 Sec...

Страница 3: ...static discharge Do not use pail liners unless they are are antistatic or conductive Connect to a grounded outlet and use grounded extensions cords Do not use a 3 to 2 adapter Do not use a paint or a...

Страница 4: ...t parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in whic...

Страница 5: ...tion H J K M N S T P R F E D B C ps A G A Pressure control B Power Cord C ON OFF switch D Digital Display E Prime Spray valve F Filter G Fluid outlet H Siphon tube J Drain tube K Pump M Hose N Spray G...

Страница 6: ...ontainer follow local code Object being sprayed follow local code Power Requirements 230V units require 220 240 VAC 50 60 Hz 8A 1 phase Extension Cords If an extension cord is necessary use a 3 wire 1...

Страница 7: ...uch as paper or cardboard which interrupts grounding continuity Grounding a metal pail connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground such as a wate...

Страница 8: ...been fully relieved after following these steps VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually then loosen completely Now clear tip or hose obstruction...

Страница 9: ...er OFF 8 Plug power supply cord into a properly grounded electrical outlet 9 Turn prime valve down 10 Place siphon tube set in grounded metal pail par tially filled with flushing fluid Attach ground w...

Страница 10: ...leaks with hand or a rag If leaks occur do Pressure Relief Tighten fit tings Do Startup 1 5 page 10 If no leaks pro ceed to 6 7 Place siphon tube in paint pail 8 Trigger gun again into flushing pail u...

Страница 11: ...sure adjustment can not eliminate heavy edges 2 Hold gun perpendicular 10 12 in from surface Spray back and forth overlapping by 50 To pre vent heavy spots before pulling trigger first move gun using...

Страница 12: ...er put safety ON 2 Rotate SwitchTip 3 Take safety OFF 4 Trigger gun to clear clog Never point gun at your hand or into a rag 5 Put safety ON 6 Return Switch to original position 7 Take safety OFF and...

Страница 13: ...ower ON Turn prime valve horizontal 7 Hold gun against paint pail Take trigger safety OFF Trigger gun and increase pressure until flushing fluid appears 8 Move gun to flushing pail hold gun against pa...

Страница 14: ...Open prime valve 13 Remove filters from gun and sprayer if installed Clean and inspect Install filters 14 If flushing with water flush again with mineral spir its or Pump Armor to leave a protective c...

Страница 15: ...tton turn power ON to enter Stored Data mode 3 Model number is displayed and then Data Point 1 power on time in hours is displayed NOTE FT600 595 4 Press display button to display Data Point 2 motor o...

Страница 16: ...s x 10 5 NOTE LIFE displays briefly then the number of gal lons sprayed above 1000 psi 70 bar 7 MPa Secondary Menu 1 Follow Pressure Relief Procedure page 8 2 Press DTS button and turn power switch ON...

Страница 17: ...0 Hz 230V 1 phase 10A 50 60 Hz Dimensions Weight 72 lb 33 kg Length 21 in 53 3 cm Width 20 5 in 52 1 cm Height Handle Up 39 5 in Handle Down 29 5 in Handle Up 100 3 cm Handle Down 74 9 cm Basic Wetted...

Страница 18: ...tion prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and t...