10
308219
Installation
3.
How to Size a Generator
for outdoor remote applications
Style
Hose
Control
Model
With Hydraulic
Pump Motor
WATTS (240 VAC)
Control
Pump Motor
1 Phase
3 Phase
Foam–Cat 200
NO
235839
NO
5,100
7,650
Foam–Cat 200
YES
235259
NO
8,880
11,340
Foam–Cat 400
NO
235840
NO
10,200
15,300
Foam–Cat 400
YES
235260
NO
13,980
15,300
Foam–Cat 400
YES
235840
YES
13,980
15,300
Foam–Cat 400
YES
235260
YES
13,980
15,300
4.
Mount the Heater
WARNING
ELECTRIC SHOCK HAZARD
To reduce the risk of electric shock, do
not expose the heater to rain.
If you have purchased the heater module separately,
bolt it securely to the Graco Pump Stand, part no.
217296 (see manual 307551) or to a wall. A mounting
hole diagram is on the back cover of manual 307551.
CAUTION
All critical air and fluid connections in the Foam-Cat
equipment are clearly labeled ISO or RES. Make
only ISO to ISO and RES to RES connections to
avoid fluid crossover which will permanently damage
the components.
CAUTION
If you are using a Freon injector, mount it down-
stream from the heater so it does not pass through
the heater.
Содержание FOAM-CAT 200 Series
Страница 33: ...33 308219 Notes...