Installation
6
Installation and Operation
Installation
The typical stationary installation shown in is only a
guide for selecting and installing a pump; it is not an
actual system design. Contact your Graco distributor for
assistance in designing a system to meet your needs.
.
Letters used to identify components in F
referred to in the package installation drawings,
F
. 7. Additional letter references
are used in installation drawings as necessary.
A
B
C
D
E
F
G
H
L
J
K
M
Key
A
Bleed-type master air valve
B
Air line filter
C
Air regulator and gauge
D
Air inlet
E
Ground wire
F
Pump
G
Drain valve
H
Dispensing valve
J
Fluid hose
K
Thermal relief kit (235998)
L
Air line lubricator
M
Bung adapter
N
Fluid outlet
P
Extension tube
N
P
F
IG