Installation
3A6586D
9
Installation
Accessories are available from Graco. Make certain
accessories such as hoses are adequately sized and
pressure-rated to meet the system’s requirements.
Location and Mounting
To properly locate and mount the pump, refer to
Dimen-
sions
. Always position the pump so
the driver, disconnect switch, and ADM are easily acces-
sible.
Attach a chain or hook at the proper lift location. Lift off
the pallet using a crane or a forklift. See the lift ring (E)
in
Figure 1
on page
.
Three pump mounting options are available from Graco:
a pump stand, a wall mount, and a floor mount adapter.
See
Kits and Accessories
starting on page
for infor-
mation about installing a pump using these mounting
options.
Always ensure the pump is level. If you are using the
pump stand, you can level the base using metal shims if
necessary. Secure the stand or floor mount using
anchors that are long enough to prevent the pump from
tipping.
Refer to the
Electric Driver Mounting Hole Pattern
on
page
to mount the driver to the stand or wall mount
once you have properly secured them to the floor or
wall.
Grounding
Electric pump:
the pump is grounded through the
power cord.
Fluid hoses:
use only electrically conductive hoses with
a maximum of 500 ft. (150 m) combined hose length to
ensure grounding continuity. Check the electrical resis-
tance of the hoses. If the total resistance to ground
exceeds 29 megaohms, replace the hose immediately.
Dispense valve:
ground through connection to a prop-
erly grounded fluid hose and pump.
Fluid supply container:
follow local code.
Solvent pails used when flushing:
follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a non-conductive sur-
face, such as paper or cardboard, which interrupts the
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure:
hold a metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.
Power Requirements
The system requires a dedicated circuit protected with a
circuit breaker.
NOTICE
Always lift the pump at the proper lift location (E). Do
not
lift in any other way. Failure to lift at the proper lift
location can result in damage to the pump system.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Voltage
Phase
Hz
Current
200-240 VAC
1
50/60
20 A
400-480 VAC
1
50/60
10 A
Содержание E-Flo SP
Страница 45: ...California Proposition 65 3A6586D 45...