Install Driver
D200 3 in. and D200s 6.5 in. Ram Supply
Units
55 gallon platen:
1. Using a capable hoist, insert tie rods into the Dis
-
placement Pump (AC) and secure the Driver (AB) to
the Pump (AC).
a. See
Reconnect Displacement Pump
in your
Pump package manual.
b. Install threaded rod (126) through center hole in
the crossbar. Install lock washers (124) and
nuts (125) onto threaded rod (126), both above
and below crossbar. Use wrench to hold lift ring
adapter (127) and tighten threaded rod (106)
into lift ring adapter (127) using another wrench.
See F
IG
. 50.
c. Tighten nut (125) below crossbar to 25 ft-lb (34
N•m) maximum.
d. Tighten nut (125) above crossbar to lock Driver
(AB) in place.
2. Connect power to the Driver (AB). Follow a-e of step
4 on page 50 in reverse.
3. If using an ambient system, turn the Disconnect
Switch (AZ) ON. If using a heated system, turn the
Power Junction Box Switch (AK) and the
Disconnect Switch (AZ) ON.
D60 3 in. Dual Post Supply Unit
1. Using a secure hoist, attach Driver (AB) to mounting
plate (259) with screws (255) and washers (256).
See F
IG
. 49 on page 51.
2. See
Reconnect Displacement Pump
in your
Pump package manual.
3. Connect power to the Driver (AB). Follow a-e of step
4 on page 50 in reverse.
To avoid serious injury when installing and removing
the Driver, make sure the Driver is supported at all
times.
F
IG
. 50
126
125
127
125
124