![background image](http://html1.mh-extra.com/html/graco/compact-dyna-star/compact-dyna-star_instructions-manual_2253470039.webp)
Troubleshooting
3A6941B
39
Pump in not powering ON.
The red LED on the motor is
blinking.
2 blinks indicate:
over current
pump is jammed
Remove the pump and repair with
new pump element parts.
2 blinks indicate:
over current
pump is jammed
The grease is too thick or the
ambient temperature is too cold to
pump.
Replace the grease if it is too thick
or the ambient temperature is too
cold to pump the grease.
Replace grease with correct
temperature rated grease.
3 blinks indicate the motor is losing
the signal.
Verify that the wire connections are
tight.
Correct polarity.
Replace the motor.
4 blinks indicate low voltage.
Check voltage and correct as
needed.
5 blinks indicate high voltage.
Check voltage and correct as
needed.
6 blinks indicate an over
temperature motor windings.
High duty cycle, set to 50% duty
cycle.
Remove the pump and repair with
new pump element parts, if the
pump is jammed,
Replace grease with correct
temperature rated grease.
7 blinks indicate over temperature
on motor driver.
High duty cycle, set to 50% duty
cycle.
Remove the pump and repair with
new pump element parts, if the
pump is jammed,
Replace grease with correct
temperature rated grease.
The Pump is cycling, but there is no
lubricant output from the outlet
The lubricant level in the tank is too
low.
Refill the tank.
Problem
Cause
Solution
Содержание Compact Dyna-Star
Страница 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Страница 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Страница 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Страница 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Страница 49: ...Notes 3A6941B 49 Notes...