Maintenance
36
3A6941B
33. Place the o-ring onto the check valve, and then
place into the pump outlet and tighten (torque 16
ft-lb/21.7 N•m) (F
. 68).
There is air located between the pump tube and the
tube-in-tube. Remove this air by filling it with grease to
prime the pump. If this is not done, the pump may lose
priming during operation.
34. Connect the refill pump to the fill coupler (F
F
IG
. 68
37
F
IG
. 69
Fill Coupler
Refill Pump
Refill Pump
Refill Filter
Fill Coupler
Pump
Tube-in-tube
Pump Tube
Содержание Compact Dyna-Star
Страница 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Страница 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Страница 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Страница 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Страница 49: ...Notes 3A6941B 49 Notes...