Operation
3A6941B
23
Pressure Switch
The pressure switch (T) is factory set to 3000 psi (20.7
MPa, 207 bar) (F
. 22).
When the pressure in the system reaches 3000 psi, the
pressure switch (T) closes.
Pressure Transducer
The pressure transducer (T) is used for continuous
pressure monitoring.
F
IG
. 22
Output type:
1 Switching output NO
Operating voltage:
24VDC
Current:
5A
Connection type:
Packard Metri-Pack 150 Series
Preset pressure:
3000 psi
Output type:
Analog 1- 5V
Operating voltage:
8 - 32V
Connection type:
Packard Metri-Pack 150 Series
Pressure range:
0-5000 psi
F
IG
. 23