308149
7
Installation
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section
FIRE AND EXPLOSION
HAZARD
on page 5.
1.
King Pumps:
use a ground wire and clamp. See
Fig. 1. Remove the ground screw (Z) and insert
through eye of ring terminal at the end of ground
wire (Y). Fasten ground screw back onto pump
and tighten securely. Connect the other end of the
wire to a true earth ground. Order Part No. 222011
Ground Wire and Clamp.
All Other Pumps:
use a ground wire and clamp.
See Fig. 2. Loosen the grounding lug locknut (W)
and washer (X). Insert one end of a 1.5 mm
(12
ga) minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. Order Part
No. 237569 Ground Wire and Clamp.
2.
Air and hydraulic hoses:
use only electrically
conductive hoses.
3.
Fluid hoses:
use only electrically conductive fluid
hoses.
4.
Air compressor or hydraulic power supply:
follow
manufacturer’s recommendations.
5.
Spray gun/dispensing valve:
grounding is obtained
through connection to a properly grounded fluid
hose and pump.
6.
Fluid supply container:
according to your local
code.
7.
Object being sprayed:
according to your local
code.
8.
All solvent pails used when flushing
, according to
your local code. Use only metal pails, which are
conductive, placed on a grounded surface. Do not
place the pail on a nonconductive surface, such as
paper or cardboard, which interrupts the grounding
continuity.
9.
To maintain grounding continuity when flushing or
relieving pressure
, always hold a metal part of the
spray gun/dispensing valve firmly to the side of a
grounded metal pail, then trigger the gun/valve.
Fig. 1
TI1052
Y
Z
Fig. 2
W
X
Y
Z
0864
Содержание Check-Mate 2100 A Series
Страница 6: ...6 308149 Notes...