PROBLEM

CAUSE

SOLUTION

Pump fails to operate

Restricted line or inadequate air/hydraulic
supply; closed or clogged valves

Clear; increase air/hydraulic supply.
Check that valves are open.

Obstructed fluid hose or gun/valve;
fluid hose ID is too small

Open, clear*; use hose with larger ID.

Fluid dried on the displacement rod

Clean; always stop pump at bottom of stroke;
keep wet-cup 1/3 filled with compatible solvent.

Dirty, worn, or damaged motor parts

Clean or repair; see separate motor manual.

Pump operates, but out-
put low on both strokes

Restricted line or inadequate air/hydraulic
supply; closed or clogged valves

Clear; increase air/hydraulic supply.
Check that valves are open.

Obstructed fluid hose or gun/valve;
fluid hose ID is too small

Open, clear*; use hose with larger ID.

Bleeder valve open

Close.

Air leaking into supply container

Check ram plate seal.

Fluid too heavy for pump priming

Use bleeder valve (see pages 12 and 14); use ram.

Worn packings in displacement pump

Replace packings.

Pump operates, but out-
put low on downstroke

Fluid too heavy for pump priming

Use bleeder valve (see pages 12 and 14); use ram.

Held open or worn intake valve or seals

Clear valve; replace seals.

Pump operates, but out-
put low on upstroke

Held open or worn piston valve or seals

Clear valve; replace seals.

Erratic or accelerated
pump speed

Exhausted fluid supply

Refill and prime.

Fluid too heavy for pump priming

Use bleeder valve (see pages 12 and 14); use ram.

Held open or worn piston valve or seals

Clear valve; replace seals.

Held open or worn priming piston

Clear; service.

Worn packings in displacement pump

Replace packings.

*

To determine if the fluid hose or gun is obstructed, 

relieve the pressure

. Disconnect the fluid hose and place a container at

the pump fluid outlet to catch any fluid. Turn on the air/hydraulic power just enough to start the pump. If the pump starts when
the air/hydraulic power is turned on, the obstruction is in the fluid hose or gun.

NOTE:

If you experience air motor icing, contact your Graco distributor.

Содержание Check-Mate 2100 A Series

Страница 1: ...Ratio with Kingt Air Motor 16 6 MPa 166 bar 2400 psi Maximum Fluid Working Pressure 0 7 MPa 7 bar 100 psi Maximum Air Input Pressure Part No 222901 Pump Series B 24 1 Ratio with Quiet Kingt Air Motor...

Страница 2: ...12 Hydraulic Powered Models 14 Service Troubleshooting Chart 15 Required Tools 16 Disconnecting the Displacement Pump 16 Reconnecting the Displacement Pump 18 Displacement Pump Service 19 Parts Drawi...

Страница 3: ...equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressure of the lowest rated system c...

Страница 4: ...operates before spraying Lock the gun valve trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 12 whenever you are instructed to relieve pres sure stop spraying clean c...

Страница 5: ...solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do not turn on or off any...

Страница 6: ...6 308149 Notes...

Страница 7: ...rder Part No 237569 Ground Wire and Clamp 2 Air and hydraulic hoses use only electrically conductive hoses 3 Fluid hoses use only electrically conductive fluid hoses 4 Air compressor or hydraulic powe...

Страница 8: ...ce in designing a system to suit your particular needs 01177A Fig 3 KEY A Pump B 200 Liter 55 Gallon Air Powered Ram C Pump Runaway Valve D Air Line Lubricator E Bleed Type Master Air Valve required f...

Страница 9: ...ed type master air valve E is required in your system to relieve air trapped between it and the air motor when the valve is closed see the WARNING above Be sure the bleed valve is easily accessible fr...

Страница 10: ...g the hydraulic lines immediately when they are discon nected Do not exceed 37 8 liter min 10 gpm hydraulic oil volume to the motor to avoid pump stalling For optimum pump performance keep the tempera...

Страница 11: ...ressure gauge F to monitor hydraulic oil pressure to the motor and to avoid overpressurizing the motor or displacement pump and a pressure and temperature compensated flow control valve G to prevent t...

Страница 12: ...t See Fig 5 Using the supplied wrench 104 adjust the packing nut weekly so it is just snug do not overtigh ten Follow the Pressure Relief Procedure above before adjusting the packing nut Flushing the...

Страница 13: ...rates beyond the pre set speed is available See Fig 3 on page 8 If your pump acceler ates quickly or is running too fast stop it immediately and check the fluid supply If the supply container is empty...

Страница 14: ...luid outlet pressure Always use the lowest hydraulic flow and pressure necessary to get the desired results Higher pressures cause premature tip nozzle and pump wear WARNING To reduce the risk of over...

Страница 15: ...ID Bleeder valve open Close Air leaking into supply container Check ram plate seal Fluid too heavy for pump priming Use bleeder valve see pages 12 and 14 use ram Worn packings in displacement pump Rep...

Страница 16: ...ps the rocker arms located beneath the rocker arm covers move when air is supplied to the motor Never operate the pump with the rocker arm covers removed Before servicing the pump relieve the pressure...

Страница 17: ...05 ft lb Torque to 196 210 N m 145 155 ft lb Torque to 135 169 N m 100 125 ft lb Square hole is for use with torque wrench 5 6 Torque to 129 142 N m 95 105 ft lb Torque to 312 340 N m 230 250 ft lb 10...

Страница 18: ...o people to hold the displacement pump while another reconnects it to the motor see the CAUTION above Orient the pump s fluid outlet to the air or hydraulic inlet as was noted in step 3 under Disconne...

Страница 19: ...let to loosen the housing from the cylinder 4 Lift the outlet housing off the pump and set it aside Be careful not to scratch the displacement rod 1 while removing the housing Remove the seal 39 from...

Страница 20: ...de assembly in the vise and close the jaws on the flats of the seat 8 just tight enough to hold the part Slide a brass rod through the openings in the piston guide 5 and unscrew it from the seat as sh...

Страница 21: ...G DETAIL 20 25 15 1 DETAIL OF INTAKE CHECK VALVE 17 12 39 35 19 4 Piston check valve see detail at right 01120 DETAIL OF PISTON CHECK VALVE 32 1 5 4 6 8 7 12 16 42 40 42 41 12 39 10 39 17 18 9 40 Remo...

Страница 22: ...Lubricate the intake valve packings and the inner diameter of the valve body 10 Install the pack ings one at a time in the following order with the lips of the v packings facing up the female gland 4...

Страница 23: ...into valve housing 5 6 7 Fig 11 Lips of v packings must face down Lips of v packings must face up Large bevel must face down Apply thread sealant Flat side must face up Torque to 97 106 N m 71 78 ft l...

Страница 24: ...lb Remove the pump from the vise and place it on its side 19 Check that the flats of the priming piston rod 12 are accessible below the intake housing 17 If not tap on the top of the displacement rod...

Страница 25: ...OD tie 265 mm 10 43 shoulder to shoulder 3 108 184130 COLLAR coupling 2 These parts are included in Connection Kit 235414 which may be purchased separately Model 222829 Pump Series A 12 1 Ratio with Q...

Страница 26: ...OD tie 265 mm 10 43 shoulder to shoulder 3 108 184130 COLLAR coupling 2 These parts are included in Connection Kit 235414 which may be purchased separately Model 222901 Pump Series B 24 1 Ratio with Q...

Страница 27: ...included in Connection Kit 235421 which may be purchased separately Model 222902 Pump Series B Model 246937 Pump Series A with Viscount Hydraulic Motor 0916A 101 105 108 107 106 104 102 103 Ref Part...

Страница 28: ...28 308149 Parts Model 222810 Series B Model 246934 Series A Displacement Pump 0919A 22 23 19 16 34 4 7 17 25 21 39 39 40 42 41 13 18 1 32 24 2 20 6 5 8 10 9 12 11 15 14 39 43 35...

Страница 29: ...46934 only 2 25 109213 O RING PTFE 1 32 109203 SCREW cap hex hd 5 8 11 unc 2A x 12 305 mm 6 34 165702 BODY bleeder valve 3 8 18 npt x 1 2 20 unf 2b 1 35 190128 PLUG valve 1 2 20 unf 2a 1 39 184072 SEA...

Страница 30: ...psi bar MPa gpm liters min To find Fluid Outlet Pressure MPa bar psi at a specific fluid flow lpm gpm and operating air pressure MPa bar psi 1 Locate desired flow along bottom of chart 2 Follow vertic...

Страница 31: ...bar MPa gpm liters min To find Fluid Outlet Pressure MPa bar psi at a specific fluid flow lpm gpm and operating air pressure MPa bar psi 1 Locate desired flow along bottom of chart 2 Follow vertical l...

Страница 32: ...psi bar MPa gpm liters min To find Fluid Outlet Pressure MPa bar psi at a specific fluid flow lpm gpm and operating air pressure MPa bar psi 1 Locate desired flow along bottom of chart 2 Follow vertic...

Страница 33: ...bar MPa gpm liters min To find Fluid Outlet Pressure MPa bar psi at a specific fluid flow lpm gpm and operating air pressure MPa bar psi 1 Locate desired flow along bottom of chart 2 Follow vertical l...

Страница 34: ...tlet Pressure MPa bar psi at a specific fluid flow lpm gpm and operating air pressure MPa bar psi 1 Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fl...

Страница 35: ...a bar psi at a specific fluid flow lpm gpm and operating hydraulic oil pressure MPa bar psi 1 Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid ou...

Страница 36: ...664 7 mm 26 17 in 256 8 mm 10 11 in 222835 246936 1376 1 mm 54 18 in 583 mm 22 95 in 793 1 mm 31 22 in 664 7 mm 26 17 in 256 8 mm 10 11 in 222901 1385 6 mm 54 55 in 592 5 mm 23 33 in 793 1 mm 31 22 in...

Страница 37: ...37 DIA 4 94 28 mm 3 712 101 6 mm 4 0 50 8 mm 2 0 0653 Three M16 x 2 0 Holes Bulldog King and Viscount Pumps Premier Pumps 06555 67 5 mm 2 7 in 135 0 mm 5 3 in 50 7 mm 2 0 in 101 5 mm 4 0 in 116 9 mm 4...

Страница 38: ...e buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential l...

Отзывы: