background image

13

Testing Your Monitor

Always test your monitor before using it the first time and then on a periodic basis. Before testing your monitor, 
complete the set-up process as described above.

1. Testing for Sound. Turn the Nursery Unit and Parents' Unit on, making sure they are both set to the same  
channel. On the Nursery Unit, switch to the "Sound Only" function. Have someone else speak into the Nursery Unit 
or place a radio near the Nursery Unit while you take the Parents' Unit into another room. You should hear the 
sounds being transmitted from the Nursery Unit. If there is no sound, adjust your volume control and/or refer to the 
Troubleshooting section on page 14. If you experience interference or static, switch both units to the other channel.

2. Testing for Movement. Switch the Nursery Unit to the "Sound & Movement" function. The Movement Indicator 
Light on the Nursery Unit will flash red, green, and then emit a single "Tic" sound. Gently pat your hand on the 
mattress. The green Movement Indicator Light will continue to flash with every movement. The Nursery Unit will 
also tick with every movement. Remove your hand from the mattress. Due to no movement, the ticking will stop, 
the Movement Indicator Light will stop flashing, and a pre-alarm beep will sound after 15 seconds. Five seconds 
later the alarm will sound and the red Alarm Indicator Light will flash continuously. 

You can also test for movement with the Nursery Unit set to the “Tic Off” position. In this case, you will not hear a 
constant ticking when you touch the mattress. When you remove your hand from the mattress the Movement 
Indicator Light will stop flashing, a pre-alarm beep will sound after 15 seconds, and five seconds later the alarm will 
sound and the red Alarm Indicator Light will flash continuously. 

To turn off the alarm, turn the Nursery Unit off or pat your hand lightly on the mattress so the Sensor Pad will  
redetect movement. The red Alarm Indicator Light on the Nursery Unit will continue to flash for one minute and it 
will then revert to green.

If the alarm does not sound when you are not touching the mattress, the Sensor Pad may be detecting a continu-
ous vibration from another source from inside and/or outside your baby's room. Common sources of this interfer-
ence are crib mobiles, fans, washing machines, or even loud music. Therefore, it is very important to make sure all 
vibration sources are eliminated before using the monitor. Place the crib near a solid supporting wall and away 
from strong air currents. Do not use crib mobiles or accessories that may cause vibrations. Avoid contact with the 
crib when the monitor is in use. 
If you find the alarm will still not sound when you are not touching the mattress or crib, the monitor is on, and you 
have removed all external sources of vibration, the sensitivity level may need to be decreased. Please refer to the 
Movement Sensitivity Adjustment section on page 11.

3. Testing for Battery Power. Verify that the units are operating on battery power by installing four AAA batteries in 
each unit and unplugging the AC adapters. The green Power Indicator should light up on all units.

Содержание Angelcare

Страница 1: ...1 Micro Tic Alarm Low Batt Movement Sensor With Sound Monitor OWNER S MANUAL KEEP INSTRUCTIONS FOR FUTURE REFERENCE 2008 Graco ISPD026BB 11 08...

Страница 2: ...b shower wash basin sink laundry tub swimming pool wet basement etc Keep Nursery Unit away from heat sources such as fireplaces radiators stoves and TVs or other appliances Heat can damage the case or...

Страница 3: ...n the monitor is in use do not use a crib mobile or other crib accessories that may produce vibrations Other sources of vibrations may include fans washing machines loud music etc These sources of vib...

Страница 4: ...r in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to...

Страница 5: ...Indicator Flashes Green Alarm Indicator Flashes Red Poor Movement Indicator Flashes Orange Power Switch Channel Selector Power Indicator Solid Green Low Battery Indicator Solid Orange Movement Sensit...

Страница 6: ...negative to negative and replace the battery cover Replace the batteries when the Low Battery Indicator flashes and turns orange instead of green IMPORTANT Charge the batteries for 15 hours prior to f...

Страница 7: ...ries can be used but they will NOT be recharged in the Nursery Unit by plugging in the AC adapter They will have to be removed and recharged in an external charger To insert batteries remove the batte...

Страница 8: ...under the center of the crib mattress with the blue side facing up Do not place any loose bedding or linen between the crib mattress and the Sensor Pad The Sensor Pad must rest on a flat firm surface...

Страница 9: ...he Tic will stop and after 20 seconds the alarm will sound Tic Off In this mode you will not hear a Tic with every movement You will still hear your baby s sounds and see sound lights and your baby s...

Страница 10: ...e Nursery Unit set to the Tic Off position In this case you will not hear a constant ticking when you touch the mattress When you remove your hand from the mattress the Movement Indicator Light will s...

Страница 11: ...o see if the Sensor Pad is resting on a flat firm surface Place the crib near a solid supporting wall and away from strong air currents Do not use crib mobiles or accessories that may cause vibrations...

Страница 12: ...d to place a piece of Masonite board under the pad This support must be at least 13 inches long on all four sides and 1 4 inch thick Only use your Angelcare monitor in a stationary sleeping environmen...

Страница 13: ...s case you will not hear a constant ticking when you touch the mattress When you remove your hand from the mattress the Movement Indicator Light will stop flashing a pre alarm beep will sound after 15...

Страница 14: ...baby s movements because the sensitivity level is too low Sensor Pad is not in full contact with the crib mattress or is not resting on a flat firm surface Baby has moved far away from the Sensor Pad...

Страница 15: ...ferent channels Volume level is too low Unplug and reconnect the cord Avoid contact with the crib when monitor is on Place crib near a solid supporting wall to avoid Sensor Pad from detecting movement...

Страница 16: ...e channel One of the units is not on The Parents Unit is located near motorized devices fluorescent lights television etc Units are too close to each other The volume is too high Check or replace batt...

Страница 17: ...17 Notes...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...0 Oaklands Blvd Exton PA 19341 www gracobaby com or 1 800 345 4109 To register your Graco product from within the U S A visit us online at www gracobaby com productregistration We currently do not acc...

Страница 21: ...1 Micro Tic Alarm Low Batt Detector de movimiento con monitor de sonido MANUAL DEL PROPIETARIO GUARDE LAS INSTRUCCIONES PARA USO FUTURO 2008 Graco ISPD026BB 11 08...

Страница 22: ...dad No use la unidad del dormitorio a la intemperie No use la unidad del dormitorio cerca de posibles lugares h medos tales como ba era ducha lavadero fregadero lavarropa piscina s tano h medo etc Man...

Страница 23: ...n apagadas cuando no las usa Si experimenta alguna interferencia cambie el canal en ambas unidades Cuando usa el monitor no use el m vil de la cuna ni otros accesorios que puedan producir vibraciones...

Страница 24: ...quipo causa interferencia peligrosa con la recepci n de radio o televisi n lo cual se puede determinar apagando y encendiendo el equipo se sugiere al usuario que trate de corregir la interferencia a t...

Страница 25: ...e alarma destella rojo Indicador d bil de movimiento Indicador de encendido verde s lido Indicador de pilas descargadas anaranjado s lido Ajuste de la sensibilidad al movimiento Enchufe de la almohadi...

Страница 26: ...Cambie las pilas cuando el indicador de pilas descargadas destelle y tenga color anaranjado en lugar de verde IMPORTANTE Cargue las pilas durante 15 horas antes de usarlas por primera vez Aseg rese de...

Страница 27: ...idad del dormitorio enchuf ndola en el adaptador de corriente alternada Tendr que sacarlas y cargarlas en un cargador externo Para instalar las pilas saque la tapa de las pilas de atr s de la unidad P...

Страница 28: ...ADILLA DEL DETECTOR fig 1 ALMOHADILLA DEL DETECTOR Ver las figuras 1 y 2 Ponga la almohadilla del detector debajo del centro del colch n de la cuna con el lado azul mirando hacia arriba No ponga ropa...

Страница 29: ...funciones siguientes Sonido y movimiento Podr escuchar los sonidos de su beb ver luces de sonido y escuchar un sonido tic con cada movimiento que haga su beb Si no se detecta ning n movimiento el tic...

Страница 30: ...unidad del dor mitorio continuar destellando durante un minuto y luego pasar a verde Si la alarma no suena cuando no toca el colch n la almohadilla del detector podr a detectar una vibraci n continua...

Страница 31: ...almohadilla del detector est sobre una superficie firme y plana Ponga la cuna cerca de una pared s lida de apoyo y lejos de fuertes corrientes de aire No use m viles o accesorios en la cuna que pudie...

Страница 32: ...bajo de la almohadilla Este apoyo debe tener por lo menos 13 pulgadas de largo en los cuatro costados y un cuarto de pulgada de espesor Use solamente su monitor Angelcare en un ambiente estacionario p...

Страница 33: ...da en la posici n Tic Off tic apagado En este modo no escuchar el sonido tic constantemente cuando toca el colch n Cuando saca la mano del colch n la luz indicadora del movimiento dejar de destellar s...

Страница 34: ...no est en contacto pleno con el colch n de la cuna o no est puesta sobre una superficie firme y plana El beb se ha movido fuera de la almohadilla del detector Apague la unidad del dormitorio Aseg res...

Страница 35: ...esenchufe y vuelva a conectar el cord n Evite el contacto con la cuna cuando el monitor est activado Ponga la cuna cerca de una pared s lida de apoyo para evitar que la almohadilla del detector detect...

Страница 36: ...e metal Una o ambas unidades no est n en la posici n vertical Las pilas est n descargadas Las unidades para padres y del dormitorio est n demasiado separadas Las unidades no est n programadas en el mi...

Страница 37: ...17 Notas...

Страница 38: ...18 Notas...

Страница 39: ...19 Notas...

Страница 40: ...ands Blvd Exton PA 19341 www gracobaby com o 1 800 345 4109 Para registrar su producto Graco desde dentro de los EE UU vis tenos en l nea en www gracobaby com productregistration Actualmente no acepta...

Отзывы: