8
310570
Setup
Connect the Fluid Lines
Fig. 1. Connect system fluid supply line to the circula-
tion package at fluid outlet (A). Close filter ball valves
(E) to isolate the circulation package from the main
fluid supply line.
Connect circulation package to the system fluid return
line at fluid return (T). Close fluid return valve (U) to
isolate the circulation package from the main fluid
return line.
Bring a hydraulic supply line from the facility hydraulic
supply (Z) to the circulation package location. Be sure
lines are properly sized and pressure-rated for the
system. Use only electrically conductive hoses.
Install a bleed-type shutoff valve (W) in the hydraulic
line to isolate the components for servicing.
Using the Quick Connectors
Fig. 2. To open a quick connector (A), loosen the
captive screw (B) and open the connector. Slide the
desired component into or out of the connector, close,
and tighten the screw.
06278
Fig. 2
B
A