Operation
3A8848A
23
7. Turn off the remote filling station pump (F).
8. Pull out and hold the pressure relief knob (T) long
enough to relieve the pressure between the fill
manifold (N) and the auto-fill shut off valve (B) and
between the remote filling station pump (F) and the
fill manifold (N).
NOTE:
The length of time to vent varies upon the
system design and installation. In some installations it
may be necessary to repeat Step 8.
9. Disconnect the supply hose (J) at the fill coupler
(M).
10. Replace the yellow dust cover for the fill coupler
(M).
Remote Fill without Remote Fill Manifold
The referenced letters used in the following instructions
refer to F
1. A supply hose pressure relief valve (Y) and overflow
container (W), that collects excess fluid that drains
during pressure relief, must be installed in an easily
accessible location between the remote filling
station pump (F) and the auto-fill shut off valve (B).
This pressure relief valve is used to relieve pressure
in the refill line and to reset the Auto-Fill Shut Off.
See
Pressure Relief Kit 247902 is available from Graco.
Contact your distributor or Graco Customer Service
for additional information.
2. Connect the supply hose (J) at the quick
disconnect (V).
3. Turn on remote filling station pump (F) and fill the
G5 reservoir (D) until the indicator pin on the
auto-fill shut off valve (B) is pushed up (see F
. 17).
The pressure in the refill pump (F) increases and the
pump stalls.
4. Turn off the air supply (H) to the refill pump (F).
5. Relieve remote filling station pump pressure
following the
Remote Filling Station Pressure
procedure, page 24.
6. Disconnect the supply hose (J) from the quick
disconnect (V).
F
IG
. 17
Pin up