Operation
24
3A8848A
Remote Filling Station Pressure Relief
The reference letters used in the following instructions
refer to F
The following Pressure Relief Procedure is only
used with the Auto-Fill Shut Off valve to relieve
remote filling station and lubricant supply line
pressure.
1. To relieve pressure between the refill pump (F) and
the auto-fill shut off valve (B), open the supply hose
pressure relief valve (Y) (F
. 18). The pressure
releases and excess fluid drains out of the drain
tube (L) and into the lubrication overflow container
(W).
2. Close the supply hose pressure relief valve (Y) after
all pressure has been relieved.
Fill with Oil
• Only use oil appropriate for the application,
automatic dispensing, and the equipment’s
operating temperature. Consult with machine and
lube manufacturer for details.
• The reservoir can be filled using a hand operated
pump, pneumatic pump or electric transfer pump.
• No not overfill (F
. 19).
• Do not operate the G5 pump without a reservoir
attached.
• Only use oils with a viscosity of at least 40 cSt.
1. Remove the fill cap (F
. 19).
2. Pour the oil into the reservoir to the max fill line
3. Replace the fill cap, and hand tighten, securely
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid, and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.
F
IG
. 18
Y
L
W
F
IG
. 19
Fill Cap
Max Fill Line