45
309077
Service
Installing the E5CK Temperature
Controller
To install the E5CK controller, which replaces the
E5CS controller, perform the following procedure:
The E5CK temperature controller is part of Tempera-
ture Controller Kit, P/N 918579.
NOTE:
Before inserting the replacement E5CK con-
troller into the panel, make sure the gasket is
in place.
1. Insert the E5CK controller into the mounting hole
on the control panel (Fig. 37). Make sure the con-
troller is firmly fixed in place.
Fig. 37
CONTROL
PANEL
FLEXIBLE
RETAINERS
ADAPTER
GASKET
7986A
2. At the back of the control panel, install the adapter
on the E5CK controller (Fig. 37).
3. Tighten the two mounting screws on adapter. To
avoid damaging the E5CK controller, tighten the
screws alternately. Do not over tighten the
screws.
4. Connect the wires to the E5CK controller termi-
nals (Fig. 38). Do not over tighten the screws.
If replacing a E5CS controller, use the terminal
conversion chart listed below to make the correct
wiring connections.
Fig. 38
7986A
Table 5.
Controller Models
E5CS Terminals
E5CK Terminals
1
8
2
7
3
6
4
3
5
2
7
11
8
12
9
4
10
5
5. If applicable, use the snap pin to install terminal
cover on the E5CK controller (Fig. 39).
Fig. 39
TERMINAL
SNAP PIN
COVER
7986A
6. After replacing the E5CK controller, you must com-
plete the series of procedures that are listed under
Setting Temperature Controllers
on page 17 to
program the controller settings.
Содержание 309077
Страница 9: ...9 309077 Typical Installation 4 Regulator Air Control Module Fig 2 O C D I A E B 9402A ...
Страница 46: ...46 309077 Service For 480 VAC Supply Units Schematic Fig 40 1391 1401 1321 1331 1791 1841 To Ram Junction Box ...
Страница 47: ...47 309077 Notes ...
Страница 64: ...64 309077 Schematics 122 122 ...
Страница 65: ...65 309077 Schematics 121 121 TEMPERATURE CONTROL TEMPERATURE CONTROL ...
Страница 66: ...66 309077 Schematics 170 170 TEMPERATURE CONTROL TEMPERATURE CONTROL TEMPERATURE CONTROL ...
Страница 67: ...67 309077 Schematics 169 169 TEMPERATURE CONTROL Remove jumper if PUMP INACTIVITY TIMER is used ...
Страница 68: ...68 309077 Schematics ...
Страница 69: ...69 309077 Notes ...