12
309077
Installation
Ground The System
Ground the supply unit as instructed here and in the
individual component manuals.
WARNING
FIRE, EXPLOSION, AND ELECTRIC
SHOCK HAZARD
To reduce the risk of fire, explosion, or
electric shock:
The power source conduit is not an
adequate ground for the system. The
unit must be bonded to either the
building ground or a true earth
ground.
A qualified electrician must complete
all grounding and wiring connections
and check the resistance as
instructed on page 14.
Refer to your local code for the requirements for
a “true earth ground” in your area.
Also read and follow the warnings on page 5.
To reduce the risk of static sparking, ground the pump,
object being sprayed, and all other spraying/dispensing
equipment used or located in the spraying/dispensing
area. Check your local electrical code for detailed
grounding instructions for your area and type of equip-
ment.
Air and Fluid Hoses:
Use only electrically conductive hoses.
Dispensing/Spray Gun
Follow the dispensing/spray gun grounding instruc-
tions.
Fluid Supply Container
Ground the container according to your local code.
Object Material is Applied To
Ground the object according to your local code.
Material Drums
Ground the material drums according to your local
code. Use only metal drums placed on a grounded
surface. Do not place the drum on a nonconductive
surface, such as paper or cardboard, which interrupts
the grounding continuity.
Maintain Grounding Continuity When Purging Or
Relieving Pressure
Follow the instructions in your separate gun manual for
safely grounding your gun while purging.
Содержание 309077
Страница 9: ...9 309077 Typical Installation 4 Regulator Air Control Module Fig 2 O C D I A E B 9402A ...
Страница 46: ...46 309077 Service For 480 VAC Supply Units Schematic Fig 40 1391 1401 1321 1331 1791 1841 To Ram Junction Box ...
Страница 47: ...47 309077 Notes ...
Страница 64: ...64 309077 Schematics 122 122 ...
Страница 65: ...65 309077 Schematics 121 121 TEMPERATURE CONTROL TEMPERATURE CONTROL ...
Страница 66: ...66 309077 Schematics 170 170 TEMPERATURE CONTROL TEMPERATURE CONTROL TEMPERATURE CONTROL ...
Страница 67: ...67 309077 Schematics 169 169 TEMPERATURE CONTROL Remove jumper if PUMP INACTIVITY TIMER is used ...
Страница 68: ...68 309077 Schematics ...
Страница 69: ...69 309077 Notes ...