25
309015
Troubleshooting (cont.)
Problem
Cause
Solution
System does not vent properly
Vent valve malfunction
Injector malfunction
Too many injectors on branch line
Supply line too small
Grease too viscous
Vent line on pump module blocked
Timer pause interval too short
Repair or replace vent valve
Repair or replace injector
Reconfigure branch line to correct
Install supply line with larger diameter
Use lighter grease, NLGI #0 or lighter
for cold temperatures
Remove obstruction or replace line
Increase pause interval
Lubricant dispensed from pres-
sure relief valve
System pressure set too high
Decrease power supply pressure to
pump
Pump runs too fast
Reservoir out of lubricant
Lubricant cavitation
Leak in system
Fill reservoir
Install a follower plate
Repair leak
Pump runs without building pres-
sure
Leak in distribution system
Faulty vent valve seat
Repair leak
Replace needle and seat
Lubricant coming out of breather
Reservoir overfilled
Drain lubricant until overflow stops
Pump will not start
No air or hydraulic supply
Solenoid valve malfunction
No electrical supply to timer
Timer malfunction
Pump malfunction
Turn on air or hydraulic supply
Replace solenoid valve
Turn on electrical supply
Refer to Timer Manual 308950
Refer to Pump Manual 308955 or
309098
Содержание 309015B
Страница 3: ...3 309015 Notes ...