6. If the FTS reads properly at the Reactor but not at
the end of the hose, check cable connections.
Verify that connections are tight.
NOTE:
To assist in taking readings, order RTD Test
Kit 18E258. The kit includes two cables: one cable
with a compatible female connector and another
cable with a male connector. Both cables have
stripped wire at the other end for easy test probe
access. See the RTD Test Kit Wire Reference table.
RTD Test Kit Wire Reference
RTD Resistance vs. Temperature
WLE
Pins Wire Color
1
Brown
2
Bare
3
Blue
4
Black
5
White
RTD or FTS
Resistance Ohms
RTD or FTS
Temperature °C (°F)
843
-40 (-40)
882
-30 (-22)
922
-20 (-4)
961
-10 (14)
1000
0 (32)
1039
10 (50)
1078
20 (68)
1117
30 (86)
1155
40 (104)
1194
50 (122)
1232
60 (140)
1271
70 (158)
1309
80 (176)
1347
90 (194)
1385
100 (212)