background image

Important Isocyanate (ISO) Information

3A8502A

5

Important Isocyanate (ISO) Information

Isocyanates (ISO) are catalysts used in two component materials. 

Isocyanate Conditions

 

Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atomized 

particulates.

Read and understand the fluid manufacturer’s warnings and

 

Safety Data Sheets (SDSs) to know specific 

hazards and precautions related to isocyanates.

Use of isocyanates involves potentially hazardous procedures. Do not spray with this equipment unless you are 

trained, qualified, and have read and understood the information in this manual and in the fluid manufacturer’s 

application instructions and SDSs.

Use of incorrectly maintained or mis-adjusted equipment may result in improperly cured material, which could 

cause off gassing and offensive odors. Equipment must be carefully maintained and adjusted according to 

instructions in the manual.

To prevent inhalation of isocyanate mists, vapors and atomized particulates, everyone in the work area must 

wear appropriate respiratory protection. Always wear a properly fitting respirator, which may include a 

supplied-air respirator. Ventilate the work area according to instructions in the fluid manufacturer’s SDSs.

Avoid all skin contact with isocyanates. Everyone in the work area must wear chemically impermeable gloves, 

protective clothing and foot coverings as recommended by the fluid manufacturer and local regulatory authority. 

Follow all fluid manufacturer recommendations, including those regarding handling of contaminated clothing. 

After spraying, wash hands and face before eating or drinking.

Hazard from exposure to isocyanates continues after spraying. Anyone without appropriate personal protective 

equipment must stay out of the work area during application and after application for the time period specified 

by the fluid manufacturer. Generally this time period is at least 24 hours.

Warn others who may enter work area of hazard from exposure to isocyanates. Follow the recommendations 

of the fluid manufacturer and local regulatory authority. Posting a placard such as the following outside the work 

area is recommended:

TOXIC FUMES

HAZARD

DO NOT ENTER 

DURING

SPRAY FOAM APPLICATION
OR FOR ___ HOURS AFTER

APPLICATION IS COMPLETE

DO NOT ENTER UNTIL:

DATE:
TIME:

____________
____________

Содержание 26D001

Страница 1: ...ssional use only Not approved for use in European explosive atmospheres See page 2 for model information 100 psi 0 69 MPa 6 9 bar Maximum Air Working Pressure 315 psi 2 17 MPa 21 7 bar Maximum Fluid W...

Страница 2: ...ed 20 Air Valve Included in kit 24A351 22 Accessories 23 Performance Chart 26 Calculate Fluid Outlet Pressure 26 Calculate Pump Air Consumption 26 Pressure Conversion Chart 27 Standard Cubic Feet Minu...

Страница 3: ...not limited to A properly fitting respirator which may include a supplied air respirator chemically impermeable gloves protective clothing and foot coverings as recommended by the fluid manufacturer...

Страница 4: ...n immediately if static sparking occurs or you feel a shock Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area PRESSURIZED EQUIPMENT HAZA...

Страница 5: ...y protection Always wear a properly fitting respirator which may include a supplied air respirator Ventilate the work area according to instructions in the fluid manufacturer s SDSs Avoid all skin con...

Страница 6: ...anufacturer s warnings and Safety Data Sheets SDSs Cross contamination can result in cured material in fluid lines which could cause serious injury or damage equipment To prevent cross contamination N...

Страница 7: ...Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime When changing materials flush the equipment multiple times to ensure it is thoroug...

Страница 8: ...for required components FIG 1 Typical Installation without Circulation 3 3 WL D RES B 0 ISO A 7 Ref Description A Proportioner G Transfer Pump Air Supply Lines H Waste Containers J Fluid Supply Lines...

Страница 9: ...10 for required components FIG 2 Typical Installation with Circulation 0 0 1 1 RES B ISO A WL D 7 Ref Description A Proportioner G Transfer Pump Air Supply Lines J Fluid Supply Lines K Transfer Pumps...

Страница 10: ...ir Regulator AC Air Line Filter AD Bleed Type Master Air Valve required AE Fluid Drain Valve required AF Bung Adapter AG Grounded Air Hose 3 8 in 9 5 mm ID Minimum AH Grounded Fluid Hose AJ Pump Fluid...

Страница 11: ...2A 11 Typical Multiple Pump Lowers Installation FIG 4 Typical Multiple Pump Lowers Installation WL D RT RT ML To Proportioner AH AH AH Ref Description RT Return Tube Kit ML Multiple Pump Lowers Fluid...

Страница 12: ...ing continuity To maintain grounding continuity when flushing or relieving pressure Hold metal part of the spray gun firmly to the side of a grounded metal pail then trigger the gun A bleed type maste...

Страница 13: ...t supplied and required fluid drain valve AE to the pump outlet See Accessories on page 23 for more information on the filter and valves 4 Use the pump identification labels and bands provided to iden...

Страница 14: ...pump 2 Close the bleed type master air valve AD 3 Open the fluid drain valve AE NOTE Follow the pressure relief procedure in your proportioner manual to relieve pressure downstream from the transfer...

Страница 15: ...supply from the air motor 3 Loosen the clamp nut DN on the pump clamp DC then remove the clamp 4 Slide the air motor away from the pump and remove the air motor Install the Air Motor 1 Follow Pressure...

Страница 16: ...pressure is bled off set the air regulator to zero NOTICE Never allow the pump to run dry of the fluid being pumped A dry pump will quickly accelerate to a high speed and could cause damage to the pum...

Страница 17: ...alves or seals Service the valves or seals The pump operates but the output is low on the upstroke Held open or worn piston valve Clear or service the valve Worn or damaged valves or seals Service the...

Страница 18: ...ef Part Description Qty 1 273295 PUMP lower 1 2 273294 AIR MOTOR T4 1 3 510490 CLAMP pump 1 4 24Z963 REGULATOR quick connect 1 5 25B395 ADAPTER bung 2 in EZ removal 1 7 26D216 BAND identity res blue 1...

Страница 19: ...12 4 13 5 N m 2 1 3 Ref Part Description Qty 201 MOTOR air 2 5 in d pulse 1 202 ROD tie 3 203 RING mounting clamp air 1 204 101682 SCREW cap sch 3 205 17R693 SPRING guard T3 1 206 BRACKET clocking 1...

Страница 20: ...arts 20 3A8502A Air Motor 273294 continued WL D Torque to 11 13 ft lb 15 18 N m 1 Apply lubricant 2 Apply adhesive and then torque to 35 40 ft lb 47 4 54 2 N m 3 Torque to 95 105 in lb 10 7 11 8 N m 4...

Страница 21: ...lower 2 5 1 302 108993 PACKING o ring 2 303 BEARING 9 16 1 304 117370 PACKING o ring 1 305 15M289 CYLINDER motor 2 5 1 306 COVER bolt t4 core 2 5 motor 1 307 SEAL u cup 562 2 308 GASKET cover small 2...

Страница 22: ...Description Qty 401 124796 O RING 018 buna 2 402 SCREW m3 thread forming 2 403 RING snap 1 0 2 404 SPRING detent small 1 405 PIN detent small 1 406 15K903 PISTON air valve small 1 407 CAM detent 1 408...

Страница 23: ...Locate upstream from all other air line accessories Fluid Line Fluid drain valve AE Required in your system to relieve fluid pressure in the fluid supply lines Install the drain valve so that it point...

Страница 24: ...rainer 1 2 npt f inlet flow rate is over 50 scfm 1 4 m3 min 1 Part Description Qty 24Z963 REGULATOR quick connect 1 Part Description Qty 208630 VALVE ball 1 2 npt m x 3 8 npt f for non corrosive fluid...

Страница 25: ...included Part Description Qty 157785 FITTING swivel 1 Part Description Qty 244524 WIRE ground assembly 1 Ref Description Qty 1 HOSE coupled 15 ft 3 2 COUPLER line air 3 3 VALVE needle 3 4 FITTING line...

Страница 26: ...pecific fluid flow gpm and air pressure psi use the following instructions and FIG 5 Locate desired fluid flow along bottom of chart Follow the vertical line to the intersection with the selected air...

Страница 27: ...r 0 22 MPa 125 psi 8 6 bar 0 86 MPa 41 7 psi 2 8 bar 0 28 MPa 150 psi 10 3 bar 1 03 MPa 50 0 psi 3 4 bar 0 34 MPa 200 psi 13 7 bar 1 37 MPa 66 7 psi 4 5 bar 0 45 MPa 250 psi 17 2 bar 1 72 MPa 83 3 psi...

Страница 28: ...Dimensions 28 3A8502A Dimensions Ref Dimension Measurement A Overall Length 50 1 in 127 2 cm B Pump Length 33 9 in 86 1 cm AK Air Inlet 1 4 in npt f AL Fluid Outlet 3 4 in npt f...

Страница 29: ...Recycling or Disposal End of Product Life At the end of a product s useful life recycle it in a responsible manner California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm w...

Страница 30: ...s 0 128 liters Maximum ambient operating temperature 120 F 49 C Maximum fluid temperature 190 F 88 C Inlet Outlet Sizes Air inlet size 1 4 18 in npt f Fluid outlet size 3 4 14 in npt f Materials of Co...

Страница 31: ...Notes 3A8502A 31 Notes...

Страница 32: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...

Отзывы: