background image

3A6673B

EN

Installation and Operation 

SDP8/SDP18 Preset 
Metered Dispense Valve

Pulse FC Enabled

For dispensing oil, automatic transmission fluid (ATF), gear oils, and antifreeze. 

Not approved for use in explosive atmospheres or hazardous locations. For professional 
use only.

See page 6 for model information.

1500 psi (10 MPa, 103 bar) Maximum Working Pressure

Important Safety 
Instructions

Read all warnings and instructions 
in this manual and related system 
manuals before using the 
equipment. Save all instructions. 

NOTICE

The metered dispense valve is designed to 
dispense petroleum-based lubricants, and 
antifreeze only. Brake cleaner and/or harsh 
solvents may damage the plastic 
components.

Содержание 26C354

Страница 1: ...s For professional use only See page 6 for model information 1500 psi 10 MPa 103 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and relate...

Страница 2: ...tallation 10 Pressure Relief Procedure 10 Grounding 10 Pre Installation Procedure 10 Flushing 11 Install the Metered Dispense Valve 11 Install the Extension Tube 12 Install the Nozzle 12 Preset Mode 1...

Страница 3: ...libration 29 Manual Calibration 30 DISPENSE 31 Screen Identification 31 UTILITY MENU 33 Service 35 Battery Replacement 35 Parts 36 Parts 37 Related Kits 37 Troubleshooting 38 Error Codes 40 Technical...

Страница 4: ...diately EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or...

Страница 5: ...not plug or unplug power cords or turn lights on or off when flammable fumes are present Use only grounded hoses Stop operation immediately if static sparking occurs or you feel a shock Do not use equ...

Страница 6: ...Antifreeze Antifreeze 8 30 26C364 1 2 BSPP Flexible Automatic Oil 8 30 26C365 1 2 BSPP Flexible Antifreeze Antifreeze 8 30 26C368 1 2 BSPP Rigid High Flow Oil 18 68 26C369 1 2 BSPP Flexible High Flow...

Страница 7: ...gation ARROWS UP DOWN LEFT RIGHT and a center ENTER button Arrows Move the cursor on the display ENTER button Used to select or store an entry Locking and Unlocking the Trigger The locking trigger fea...

Страница 8: ...Overview 8 3A6673B Opening and Closing the Nozzle To open the nozzle rotate the nozzle clockwise To close the nozzle rotate the nozzle counter clockwise FIG 3 Open Closed...

Страница 9: ...g the metered dispense valve on a console Oil Bar An Oil Bar Kit is available for mounting one to three metered dispense valves Contact your Graco Distributor for ordering details NOTE The Utility Men...

Страница 10: ...ation Procedure 1 See Relieve pressure page 10 2 Close fluid shut off valve B FIG 4 page 9 3 Ground the hose and reel or console see Grounding page 10 4 Flush equipment See Flushing page 11 This equip...

Страница 11: ...the container to avoid it becoming loose during flushing c For multiple dispensepositions first flush the dispense position farthest from the pump then work toward the pump 4 Slowly open the fluid shu...

Страница 12: ...e wrench on the flats of the nozzle bushing tighten firmly FIG 10 3 Opentheautomatictwistlocknozzleand all fluid shut off valves Start pump to pressurize system 4 Toensuredispensingaccuracy purgeall a...

Страница 13: ...valve should be calibrated prior to using it for the first time Calibrating the metered dispense valve assures that the dispenses are accurate Calibration factors can vary due to fluid viscosity and...

Страница 14: ...se valve calibration FIG 15 NOTE The on this screen is used for Manual Calibration See Manual Calibration instructions on page 15 6 Dispense exactly one quart or one liter of fluid into the one quart...

Страница 15: ...d to set that number 1 Follow steps 1 4 of the Calibration instructions beginning on page 13 2 Use the RIGHT ARROW button on the keypad to highlight and press the center ENTER button on the keypad to...

Страница 16: ...sized clean calibrated volumetric flask Note this volume as the VOLUME DISPENSED see Calculating k factor Step 11 page 18 2 Record the volume displayed on the metered dispense valve Note this volume a...

Страница 17: ...the RIGHT ARROW button on the keypad to highlight and press the center ENTER button on the keypad to select the option FIG 27 8 The k factor adjustment screen shown in FIG 28 displays 9 Use the UP and...

Страница 18: ...ENSE A BANNER Unique identification name See Utility Menu Set Up BANNER page 23 for instructions for creating the banner B BATTERY INDICATOR When the batter ies are fully charged the battery is com pl...

Страница 19: ...mount of fluid previ ously dispensed K INCREASE DECREASE ARROW The up down arrow on the screen indicates the user can increase or decrease the PRESET quantity before starting the dispense Use the UP o...

Страница 20: ...If RESET was selected the field will show 0 000 STOP Function During the dispense the word STOP FIG 32 is highlighted on the lower left corner of the dispense screen To interrupt the dispense at any...

Страница 21: ...e unit of measurement displayed is determined by the Unit of Measurement criteria selected in UTILITY MENU SET UP UNIT OF MEA SURE page 23 GO BACK Returns to Main Menu screen RESET Resets the Resettab...

Страница 22: ...ays the meter is ready to use SET UP SCREENS The SET UP Menu includes the following options UNIT OF MEASURE BANNER CALIBRATE and A second SET UP screen is accessed by selecting the This screen include...

Страница 23: ...assign a name to the meter such as Meter 1 Meter 2 etc This is useful in shops that have more than one meter in their system Names can be made up of anycombination of letters or numbers The maximum nu...

Страница 24: ...uage screen it can be configured to display in ENGLISH FRENCH GERMAN ITALIAN A second language screen is accessed by selecting the This screen includes language options of POLISH PORTUGUESE RUSSIAN AN...

Страница 25: ...option is being set up The example in FIG 46 shows PRESET1 This means you are setting up the PRESET parameters for PRE SET1 in the list R NAME Additional information about the PRESET such as the type...

Страница 26: ...to PRESET Menu Screen FLIP DISPLAY Allows for viewing data on the metered dispensevalvedisplayupsidedownforoilbar installation After selecting FLIP DISPLAY the meter display goes blank for about 10 s...

Страница 27: ...button after RESET is selected Continue to step 4 4 Press and hold the LEFT ARROW button 5 While still holding down the LEFT ARROW button press the CENTER button DEVICE INFORMATION See page 21 for a...

Страница 28: ...ds When a tag or voucher is referenced in this manual it refers to a card programmed to perform the designated function Enable Pulse FC Mode 1 Press the center ENTER button on the keypad to activate t...

Страница 29: ...first time Calibrating the metered dispense valve assures that dispenses are accurate Calibration factors can vary due to fluid viscosity and flow rate Calibrate the metered dispense valve for specif...

Страница 30: ...ER button on the keypad to select END A screen displaying the quantity of fluid dispensed displays FIG 61 shows an example of the dispensed volume screen 7 Press the center ENTER button on the keypad...

Страница 31: ...r ENTER button on the keypad to select ENTER and save the new calibration factor AfterselectingENTERtheMainMenu screen shown in FIG 66 displays DISPENSE Screen Identification A BANNER Name of the flui...

Страница 32: ...the total amount of fluid that can be dispensed Adjustments cannot be made to these parameters 3 Squeeze the trigger to begin dispensing fluid A numeric volume of dispensed fluid displays in field D...

Страница 33: ...reen shown in FIG 69 displays 3 If UTILITY MENU is not highlighted use the DOWN ARROW on the key pad to highlight it 4 Press the center ENTER button on the key pad to select UTILITY MENU 5 The UTILITY...

Страница 34: ...ilbar installation After selecting FLIP DISPLAY the meter display goes blank for about 10 seconds After approximately 10 seconds the screens shown in FIG 72 FIG 73 display When the MAIN MENU Screen sh...

Страница 35: ...To change the battery 1 Remove screws 36 from the battery compartment cover 5 2 Use a small flatscrewdriver to gently pry the cover away from the metered dispense valve housing on the bottom side of...

Страница 36: ...Parts 36 3A6673B Parts FIG 78 19 37 29 28 27 5 36 2 3 14 17 21 20 15 18 6 16 10 4 13 12...

Страница 37: ...0 3 4 14 BSPP 10 155332 PACKING o ring 1 12 HOUSING metered dispense valve 1 13 131258 PACKING square ring 1 14 25D904 VALVE metered dispense valve assy 1 15 25M601 1 16 129830 COVER trigger guard 1 1...

Страница 38: ...If the problem remains contact your Graco distributor for repair or replacement Pump pressure is low Increase pump pressure Twist lock nozzle not fully open Aim nozzle into bucket or rag Fully open no...

Страница 39: ...e connection Apply PTFE tape leave a minimum of two engaged threads uncovered for electrical continuity or sealant to threads of hose and tighten the connection Poor swivel metered dispense valve hous...

Страница 40: ...al gear Ensure that your flow rate is not higher than 18 gpm 68 lpm For further assistance contact your Graco distributor Reed switch malfunction Replace electronic bezel housing Unit was dropped or u...

Страница 41: ...maximum recorded dispensed volume 9999 units maximum preset volume 9999 units Inlet 1 2 14 npt or 3 4 14 npt Outlet 3 4 16 straight thread o ring boss Operating temperature range 4 F to 158 F 16 C to...

Страница 42: ...including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e au...

Страница 43: ...le obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for...

Страница 44: ...hanges at any time without notice Original instructions This manual contains English MM 3A6673 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES...

Отзывы: