Reassembly
1. Place the relief ball (7) i into position in the pump
housing (see F
. 43).
2. Replace the spring guide (8) (see F
3. Replace the spring (9) (F
. 43).
4. Tighten the relief valve housing into the pump
housing (F
. 43).
NOTE: Do not loosen the cap nut and nut since this will
change the pressure setting.).
information
beginning on page 9.
Pump Outlet Check Valve
Replacement with Thermal
Relief P/N 133097
Disassembly
1. Follow
2. Turn off and disconnect the power to the pump.
3. Remove the standard check valve (17) from the
outlet fitting (18) (F
. 44).
Reassembly
1. Tighten the outlet check valve with built-in thermal
relief (Torque 30 ft-lbs, 40.7 N•m).
information
beginning on page 9.
F
IG
. 44
17
18