Repair
3A8571A
21
Reassembly
1. Put the pump housing assembly onto the motor.
The motor shaft key should match the slot on the
gear on the inside cover. The pump outlet should
face up and the terminal box should be centered
between the pump outlet and the pump inlet
2. Place and tighten the four Allen screws (6) using an
5/16 in. (8 mm) hex wrench (torque 20 ft-lbs)
. 22).
3. Push the pressure switch wires into the wire clamp,
through the terminal box and through the strain
relief (see F
. 21).
4. Crimp the connectors to the end of the pressure
switch wires (see F
5. Twist the strain relief nut on using a wrench until
tightened (see F
. 21).
6. Connect the pressure switch wires to the toggle
switch and relay terminal (F
7. Place the gasket onto the terminal box.
8. Replace the terminal box cover.
9. Insert the four terminal box cover screws and
tighten, making sure that the grounding wire is
connected properly (see F
. 27).
F
IG
. 24
F
IG
. 25
Motor Shaft Key
Gear Slot
Inlet
Outlet
Terminal Box
F
IG
. 26
Pressure
Switch Wires
Toggle Switch and
Relay Terminal