background image

Installation

3A8571A

11

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever 

you see this symbol.

1. Turn off and disconnect the power to the pump.

2. Open the dispense valve into a grounded waste 

container to relieve pressure.

3. Close the dispense valve.

Duty Cycle

The pump is designed to operate at a 50% duty cycle. 

It can operate up to a maximum of 30 minutes of run 

time, with an equal amount of down time. 

This equipment stays pressurized until pressure is 

manually relieved. To help prevent serious injury from 

pressurized fluid, such as splashing fluid and moving 

parts, follow the Pressure Relief Procedure when you 

stop dispensing and before cleaning, checking, or 

servicing the equipment.

NOTICE

Never allow the pump to operate dry. Make sure that 

the pump has fluid in it when the pump is initially 

installed. Do not run the pump for more than five (5) 

minutes with the pump discharge blocked. Do not 

operate the pump continuously more than 30 minutes 

in one (1) hour. Failure to follow these instructions can 

result in damage to the pump.

Содержание 25T818

Страница 1: ...Do not use to pump water For professional use only Not approved for use in explosive atmospheres or hazardous classified locations 25T818 Gear Pump 3 8 gpm 14 4 lpm 300 psi 2 07 MPa 20 7 bar Maximum...

Страница 2: ...essure Relief 12 Recycling and Disposal 13 End of Product Life 13 Troubleshooting 14 Repair 16 Replace Clean Suction Screen P N 133377 16 Outlet Assembly Kit P N 133413 17 Pump Housing Assembly P N 13...

Страница 3: ...Equipment surfaces and fluid that is heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipment EQUIPMENT MISUSE HAZARD Misuse can cause death or serious in...

Страница 4: ...ctions before operating the equipment Check hoses tubes and couplings daily Replace worn or damaged parts immediately PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the wo...

Страница 5: ...13 8 bar while pumping the fluid Exceeding this pressure can cause the motor to cycle on and off repeatedly The output pressure varies at the time of pump shut off It is determined by many factors inc...

Страница 6: ...Typical Installation 6 3A8571A FIG 2 Typical Installation Option 2 Pump with Hose Reel FIG 3 Typical Installation Option 3 Pump with More Than One Hose Reel...

Страница 7: ...on 3A8571A 7 Component Identification Key A Motor with relay B Pressure switch C Pressure relief valve D Outlet check valve G Inlet check with thermal relief H Outlet 1 2 npt J Pump K Power Switch FIG...

Страница 8: ...Typical Installation 8 3A8571A Pump Wiring FIG 5...

Страница 9: ...tion page 7 When activated the valve relieves pressure back to the tank Mount Pump on Tank with Suction Tube 1 Install the bung adapter 15 in the tank bung and tighten 2 Use a 3 4 in 19 mm steel or PV...

Страница 10: ...st of the motor or the motor will run continuously Ensure that the small red wire remains on the front post FIG 6 Priming 1 Attach a priming hose to the outlet of the pump Insert the opposite end of t...

Страница 11: ...his equipment stays pressurized until pressure is manually relieved To help prevent serious injury from pressurized fluid such as splashing fluid and moving parts follow the Pressure Relief Procedure...

Страница 12: ...e power switch located on the terminal box of the motor ON 2 Place the outlet of the dispensing valve into the fill container 3 Open the dispensing valve to the full open position until the desired am...

Страница 13: ...nd recycle it in a responsible manner Perform the Pressure Relief Procedure Drain and dispose of fluids according to applicable regulations Refer to the material manufacturer s Safety Data Sheet Remov...

Страница 14: ...There is an air leak in the suction tube Inspect all joints in the suction tube making sure that all threaded joints have sealant applied properly There is an air lock in the system Fill the system w...

Страница 15: ...gears are binding Make sure that the gears turn freely If not inspect the gears If damaged replace the pump housing assembly Pressure relief is relieving pressure internally at low pressure not readin...

Страница 16: ...a 3 4 in 19 mm hex wrench from the pump inlet FIG 10 8 Inspect the suction filter 13 and either clean or replace as needed Reassembly 1 Place the suction filter 13 into the pump inlet using a 3 4 in 1...

Страница 17: ...e terminal box cover gently upward off of the terminal box FIG 12 7 Remove the gasket 8 Remove the pressure switch wires from the toggle switch and relay terminal FIG 12 9 Cut the pressure switch wire...

Страница 18: ...box through the strain relief FIG 14 and FIG 15 3 Crimp the connectors to the end of the pressure switch wires FIG 16 4 Twist the strain relief nut on using a wrench until tightened see FIG 14 5 Conne...

Страница 19: ...ove the suction tube from the pump 5 Remove the four terminal box cover screws FIG 18 6 Pull the terminal box cover gently upward off of the terminal box 7 Remove the gasket 8 Remove the pressure swit...

Страница 20: ...x through the strain relief FIG 21 12 Pull the pressure switch wires out of the wire clamp FIG 21 13 Remove the four Allen screws 6 using a 5 16 in 8 mm hex wrench FIG 22 14 Remove the pump housing as...

Страница 21: ...clamp through the terminal box and through the strain relief see FIG 21 4 Crimp the connectors to the end of the pressure switch wires see FIG 26 5 Twist the strain relief nut on using a wrench until...

Страница 22: ...the suction tube from the pump 5 Remove the four terminal box cover screws FIG 28 6 Pull the terminal box cover gently upward off of the terminal box 7 Remove the gasket 8 Remove the pressure switch...

Страница 23: ...p FIG 32 13 Remove the four Allen screws 6 using a 5 16 in 8 mm hex wrench FIG 32 14 Remove the pump housing assembly from the motor FIG 23 15 Remove four screws 10 on the adapter plate 2 using a 1 2...

Страница 24: ...ly 1 Place the pump gears 3 into the pump cavity making sure that they spin freely FIG 35 2 Put the o ring 5 into the groove on the adapter plate 2 cover FIG 36 3 Position the adapter plate on the pum...

Страница 25: ...wrench torque 20 ft lbs see FIG 32 7 Push the pressure switch wires into the wire clamp through the terminal box and through the strain relief see FIG 31 8 Crimp the connectors to the end of the pres...

Страница 26: ...disconnect the power to the pump 3 Remove the pump from the tank 4 Remove the suction tube from the pump 5 Remove the relief valve housing FIG 43 NOTE Do not loosen the cap nut and nut since this wil...

Страница 27: ...pressure setting 5 Complete using the Installation information beginning on page 9 Pump Outlet Check Valve Replacement with Thermal Relief P N 133097 Disassembly 1 Follow Pressure Relief Procedure pag...

Страница 28: ...Parts 28 3A8571A Parts 1 2 5 3 4 19 10 6 16 17 18 11 7 8 9 20 13 14 12 15 1 2 Torque value 20 ft lb 27 1 N m 1 2 Torque value 30 ft lb 40 7 N m 2 21...

Страница 29: ...1 3 Gear pump 2 4 Seal shaft 1 5 O ring 1 6 Screw 3 8 16 socket head cap 4 7 Ball relief valve 1 8 Guide spring 1 9 Spring relief valve 1 10 Screw 5 16 18 x 1 4 11 Relief valve housing 1 12 Inlet che...

Страница 30: ...0 3A8571A Kits and Accessories Part Number Description 260124 Suction tube with inlet check assembly 133413 Outlet assembly kit 12 VDC On Demand Pump 133374 Pump housing assembly 12 VDC On Demand Pump...

Страница 31: ...Kits and Accessories 3A8571A 31 Pump Performance Chart 133375 Suction kit 133097 Outlet check valve with built in thermal relief Part Number Description...

Страница 32: ...Dimensions 32 3A8571A Dimensions Length A Height B Width C Models Inches mm Inches mm Inches mm 25T818 13 43 341 1 9 67 245 6 9 5 241 3...

Страница 33: ...si 0 MPa 0 bar see Pump Performance Chart page 31 3 8 gpm 14 4 L min Dimensions See Dimensions page 32 Weight All models 36 lb 16 3 kg Motor Details Voltage 12 VDC Current 60 A Power 0 75 HP 600 W Enc...

Страница 34: ...in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARR...

Отзывы: